X-Authentication-Warning: delorie.com: mail set sender to geda-user-bounces using -f X-Recipient: geda-user AT delorie DOT com X-Original-DKIM-Signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=gmail.com; s=20161025; h=mime-version:references:in-reply-to:from:date:message-id:subject:to; bh=zlTOjrzy7RP8sHyG6B8ao9b5wvS27cDGMOWt/a/bQnI=; b=Q+G2ny4mn+U15qS1p1vzrQSREpMRRdStEKilxO4yAPiXkUFC8hxLU7rKC8FU1n8X91 ym4ZiQoeApZwgxbUHZ1idYsriRicGZsEnfy6hHwvjQhdWb6tjLzCgULbq/u3lFbROnBu FZIHtIGcCIEgafL8JI7M1mPXUcaNse0QwBQVVm3/spfOLrFWogn4Bt46P8fZhZpwuzuB Cs5sHVLYfPqRMKl1iVsuNo7LieXOYYD1H6XuWGIZ5fAwNSUF5UKmvyZYifts9r6Uwc4T Mh6u3mTwlf+3Kc1zVT9+Maw6EFeLdYWN2f/L88WusxiOJSd9wxU0aWIR5jKbnqB1XV3v ZSIg== X-Google-DKIM-Signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=1e100.net; s=20161025; h=x-gm-message-state:mime-version:references:in-reply-to:from:date :message-id:subject:to; bh=zlTOjrzy7RP8sHyG6B8ao9b5wvS27cDGMOWt/a/bQnI=; b=raSIq2YtP/4jxLV5WnmtAwcZLMdXKQbL4Pp8xJbefSNmBtuLk2aWmmnC60Mc4rcBkP RVuLPNiBMF5+6GraPEnmFPes/iq0wZ1SG11xMjSH09X0UcWeTwhWa71Y815zZpN40IQY NB2VPDf3ZZp3kiq8ygDVAlIAYLVV7MT556U8ZyVJtclruv444C3QW2paUwpcsNaFtUJ7 NjB/PMJeZ0YVEyA2KPWsH6mOEcAyp3bcK2hpg9jLQVBuoXX8bzmJLPel5FgdqkJx/H5z XVLBm/1NYqI8oWSRpZdKUUS3b7WMD4qcKU//wqtcosh6FHTYITU1mTxCCsfpvy7eyJGe aX2A== X-Gm-Message-State: AOAM531i7EqtqbrDFeog2EOcqgn75ivOnMEaQEMxXK+f9yAdIVImMUhN MwDJHcouqKlvlXG86O7fNxJqzz3HmODT5k76rLUu5i35 X-Google-Smtp-Source: ABdhPJzHLXxSgCBVXj1GUgE6ZEW3uzPSuTbVp+NF8sdBEIE5K+iktFNBbbS9Gh+P0Bte61XsBBvqor4bPoOcAjYpBO0= X-Received: by 2002:a1f:964c:: with SMTP id y73mr4494915vkd.8.1602010592976; Tue, 06 Oct 2020 11:56:32 -0700 (PDT) MIME-Version: 1.0 References: <20201005230622 DOT 38e89fe7f870c827cc424103 AT gmail DOT com> <20201006194215 DOT 5cf31fc25518b03a88cb4d80 AT gmail DOT com> In-Reply-To: <20201006194215.5cf31fc25518b03a88cb4d80@gmail.com> From: "Chad Parker (parker DOT charles AT gmail DOT com) [via geda-user AT delorie DOT com]" Date: Tue, 6 Oct 2020 14:56:21 -0400 Message-ID: Subject: Re: [geda-user] PCB connect pad to plane To: geda-user AT delorie DOT com Content-Type: multipart/alternative; boundary="0000000000005224a705b1052833" Reply-To: geda-user AT delorie DOT com --0000000000005224a705b1052833 Content-Type: text/plain; charset="UTF-8" There are design rules for other non-copper objects that ought to be observed. For example, distance between an object and the edge of the board, or a hole. There's also thickness of silk screen lines, or silk lines drawn over exposed copper. On Tue, Oct 6, 2020 at 2:22 PM Nicklas Karlsson ( nicklas DOT karlsson17 AT gmail DOT com) [via geda-user AT delorie DOT com] < geda-user AT delorie DOT com> wrote: > > ... I don't agree. Ideally the DRC would also be "net-aware" (aka > > "connection-aware") so that it could have net-specific design rules, as > > well as verifying that you haven't shorted any nets together. > > Yes it must be net-aware but it should only care about all copper objects. > > > It would be > > nice to be able to set different clearances for high-voltage nets, or > > different minimum trace widths for power nets, for example. > > Without doubt and DRC is more important than online guidance. > > > In terms of priorities, when I reworked the DRC I wanted to make sure > that > > it did what it already advertised accurately (which I believe it now > does). > > That's good. > --0000000000005224a705b1052833 Content-Type: text/html; charset="UTF-8" Content-Transfer-Encoding: quoted-printable
There are design rules for other non-copper objects t= hat ought to be observed. For example, distance between an object and the e= dge of the board, or a hole. There's also thickness of silk screen line= s, or silk lines drawn over exposed copper.

--0000000000005224a705b1052833--