X-Authentication-Warning: delorie.com: mail set sender to geda-user-bounces using -f X-Recipient: geda-user AT delorie DOT com X-Original-DKIM-Signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=gmail.com; s=20161025; h=mime-version:references:in-reply-to:from:date:message-id:subject:to; bh=g8yS1dlcQ6tdIwucS8PojGZWuujCgxk91uAOouSMJTg=; b=Yos4zssXzGrQ74Zx1HxGBPHMO5sM9EhRABjRy/U939WEWSXQGC2CgZLGfX64Ibrw0+ cKcjxFcUn7oieFMDeYZ7KyRir8H9Lxe6CAUuKrmwn/UvV+bH5qz8TBPryOSo1DRfA+nf 0VyZ5RVGLTrllZM6C7BlqXaOlFIs/7iDRwGnBYsKmwgI9JqmF4YMcMvUiDAS/47S0MZn oDXpJ0cgrPM9Q6dxC4Nluz0o+ak4p7L3OdmfhiqDBDFbP+wsn1ev1iZuVvP8rTlJ4FBq uTFZFJocFyiVuZNajWSIyfNiSRumFZbnFWucw77OGhngTfS2kiiIXn2x5vC+sG37r2f0 1aTw== X-Google-DKIM-Signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=1e100.net; s=20161025; h=x-gm-message-state:mime-version:references:in-reply-to:from:date :message-id:subject:to; bh=g8yS1dlcQ6tdIwucS8PojGZWuujCgxk91uAOouSMJTg=; b=BSCgZFh8WKF/fx+P53TW7CKtp3ROiO+QZhgqgEwKngV7Aa6PAvbSglYktEnDOSrYhz Pk2dmklxEJw0kiCrgsKEXl6OAws00qzcLBsLHmrUxS4RdnjhLarnsglEuEyM7vg2dc9g 7prxtiMmJ61wW/hI69Ugkc4Wo8sD8EOpcvMhqgT+raCDjjDeXwuGmulGC/g8fqid5oO5 VemnRbPxWaT7izudXY3XIfPBAikMz9HqZnv24wpAd8k5yLrA+Fw40vTZr4MZ0loSEim5 6UlKnG8svcQ8LBdWrecCB5NaGKNGSs+duovDLkktwM1QO4cXw1yEsOTQiP+kDTZDLFk3 UVMw== X-Gm-Message-State: APjAAAX/eQgvj0vCYxpi/x1exu+HK88OyrK4GnZWG9ZfuN07nCO/qzOh WTcITcBeIs/qkcox9QQKdfJeUWRYTTrW8eMmZyBlBE61 X-Google-Smtp-Source: APXvYqz8PcVJ7m5sDIfinqjLItskRwKIPscrvyy0UDFBuvMZcCcfDnkDhFgISljy970xd5Qcqw0Hy0rgyFJBES82RSM= X-Received: by 2002:a17:90a:8c18:: with SMTP id a24mr6455066pjo.111.1562761376790; Wed, 10 Jul 2019 05:22:56 -0700 (PDT) MIME-Version: 1.0 References: <20190707230220 DOT 06dd19dc AT swips DOT iqo DOT uni-hannover DOT de> In-Reply-To: From: "Chad Parker (parker DOT charles AT gmail DOT com) [via geda-user AT delorie DOT com]" Date: Wed, 10 Jul 2019 08:22:45 -0400 Message-ID: Subject: Re: [geda-user] Fwd: Are via's present on booth side of the pcb? To: geda-user AT delorie DOT com Content-Type: multipart/alternative; boundary="000000000000bb7c41058d52bc66" Reply-To: geda-user AT delorie DOT com --000000000000bb7c41058d52bc66 Content-Type: text/plain; charset="UTF-8" Content-Transfer-Encoding: quoted-printable Yes. The other way that you can tell is to put the crosshair over the via and hit ctrl-r to bring up the report. If it says "Type =3D Through-hole." Then it goes all the way thought the board. The type isn't present in the report for pins because pins are inherently through-hole. --Chad On Mon, Jul 8, 2019 at 9:59 AM Cs=C3=A1nyi P=C3=A1l (csanyipal AT gmail DOT com) [= via geda-user AT delorie DOT com] wrote: > Chad Parker (parker DOT charles AT gmail DOT com) [via geda-user AT delorie DOT com] > ezt =C3=ADrta (id=C5=91pont: 2019. j=C3=BAl. 8., = H, 14:57): > > > > On Sun, Jul 7, 2019 at 5:39 PM Kai-Martin Knaak > wrote: > >> > >> > >> With PCB vias extend to every copper layer. Actually, there is no way = to > >> make a via one layer only. This also applies to pins, too. > >> > > > > Yes, but just to be clear: we do also support blind and buried vias, > which do not necessarily extend to every copper layer, but must exist on = at > least two layers. > > > > Cheers, > > --Chad > > So seeing my files here: > > https://drive.google.com/drive/folders/19JoFrssJjgyrIeNXurPIdccDn5UCK0Zx?= usp=3Dsharing > > are on this pcb my vias booth on top and bottom copper layers out there? > > -- > Best, Pali > > --000000000000bb7c41058d52bc66 Content-Type: text/html; charset="UTF-8" Content-Transfer-Encoding: quoted-printable
Yes.

The other way that= you can tell is to put the crosshair over the via and hit ctrl-r to bring = up the report. If it says "Type =3D Through-hole." Then it goes a= ll the way thought the board. The type isn't present in the report for = pins because pins are inherently through-hole.

--Chad

On Mon, Jul 8, 2019 at 9:59 AM Cs=C3=A1nyi P=C3=A1l (csanyipal AT gmail DOT com) [via geda-user AT delorie DOT com] <geda-user AT delorie DOT com> wrote:
<= blockquote class=3D"gmail_quote" style=3D"margin:0px 0px 0px 0.8ex;border-l= eft:1px solid rgb(204,204,204);padding-left:1ex">Chad Parker (parker DOT charles AT gmail DOT com) [via geda-us= er AT delorie DOT com]
<geda-user AT de= lorie.com> ezt =C3=ADrta (id=C5=91pont: 2019. j=C3=BAl. 8., H, 14:57= ):
>
> On Sun, Jul 7, 2019 at 5:39 PM Kai-Martin Knaak <kmk AT familieknaak DOT de> wrote: >>
>>
>> With PCB vias extend to every copper layer. Actually, there is no = way to
>> make a via one layer only. This also applies to pins, too.
>>
>
> Yes, but just to be clear: we do also support blind and buried vias, w= hich do not necessarily extend to every copper layer, but must exist on at = least two layers.
>
> Cheers,
> --Chad

So seeing my files here:
https://drive.= google.com/drive/folders/19JoFrssJjgyrIeNXurPIdccDn5UCK0Zx?usp=3Dsharing

are on this pcb my vias booth on top and bottom copper layers out there?
--
Best, Pali

--000000000000bb7c41058d52bc66--