X-Authentication-Warning: delorie.com: mail set sender to geda-user-bounces using -f X-Recipient: geda-user AT delorie DOT com X-TCPREMOTEIP: 173.48.170.224 X-Authenticated-UID: jpd AT noqsi DOT com From: John Doty Content-Type: multipart/alternative; boundary="Apple-Mail=_931A5F39-2622-44C7-B25A-C2ADC939F42F" Mime-Version: 1.0 (Mac OS X Mail 10.3 \(3273\)) Subject: Re: [geda-user] Refdes bug or Master Attribute Document on the Wiki needs update. Date: Wed, 30 Jan 2019 14:32:02 -0500 References: <9ed059c0-f3c5-1482-169b-f8f1119f3208 AT fastmail DOT com> <5BC4365D-FBD0-4495-806B-C30BA710D31B AT noqsi DOT com> <4739A346-6DB4-4250-965C-13AA19863969 AT noqsi DOT com> To: geda-user AT delorie DOT com In-Reply-To: Message-Id: X-Mailer: Apple Mail (2.3273) Reply-To: geda-user AT delorie DOT com Errors-To: nobody AT delorie DOT com X-Mailing-List: geda-user AT delorie DOT com X-Unsubscribes-To: listserv AT delorie DOT com Precedence: bulk --Apple-Mail=_931A5F39-2622-44C7-B25A-C2ADC939F42F Content-Transfer-Encoding: quoted-printable Content-Type: text/plain; charset=us-ascii > On Jan 30, 2019, at 1:27 PM, gedau AT igor2 DOT repo DOT hu wrote: >=20 > See my point? pcb-rnd is strong in that. When they can't load=20 > organization A's kicad board at organization B's protel/autotrax, = that's=20 > where you jump in with a Makefile that uses pcb-rnd to convert. No sch=20= > involved. No GUI PCB editing involved. Not funneling anything in, not=20= > locking in users.=20 I can see the use of that. One disadvantage, though, is that the layout = winds up another generation removed from the controlled schematics. Can = you test netlist topology for equivalence? John Doty Noqsi Aerospace, Ltd. jpd AT noqsi DOT com --Apple-Mail=_931A5F39-2622-44C7-B25A-C2ADC939F42F Content-Transfer-Encoding: quoted-printable Content-Type: text/html; charset=us-ascii
On Jan 30, 2019, at 1:27 PM, gedau AT igor2 DOT repo DOT hu = wrote:

See my point? pcb-rnd is strong = in that. When they can't load 
organization A's kicad board at organization B's = protel/autotrax, that's 
where you jump in with a Makefile that uses = pcb-rnd to convert. No sch 
involved. No GUI PCB editing involved. Not = funneling anything in, not 
locking in users. 

I= can see the use of that. One disadvantage, though, is that the layout = winds up another generation removed from the controlled schematics. Can = you test netlist topology for equivalence?

John Doty    =           Noqsi = Aerospace, Ltd.

jpd AT noqsi DOT com




= --Apple-Mail=_931A5F39-2622-44C7-B25A-C2ADC939F42F--