X-Authentication-Warning: delorie.com: mail set sender to geda-user-bounces using -f X-Recipient: geda-user AT delorie DOT com X-Original-DKIM-Signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=gmail.com; s=20161025; h=mime-version:in-reply-to:references:from:date:message-id:subject:to; bh=rGXbYxFkEc4p0CgaSKTThROj1+2l+YW9iPYjA7HodLI=; b=UGpRg4QovwShIRuzMCwpSuPmE88WKTDYXCvbSCKvnSFAXjSKUDnnWaEyxnlMmEcWRY 25Y5Zpt+OA8UfkZP2bBmMeJGM0g2Tn0mt4fyxWYunaQOCvFNr2AN89goJUpYvCXpstQM 6x1rPa6llryn4toXp8xu/XjIOA/frPuCWCnJJgAyxy26GKwj6ySwP/foANevdkRFBAoz StmA9uoXxf8MbSHceyKpZvLthL+7ioSeX3uEBg6dftQRbruk9ZeRiiKydCuTbMHSqMTp ItkXuHgty7E6C/JPd3nThmr2OS+7ZCg3pkfqKYRkV96XIBBYvVsnfZETJLAbtdMEyzCD Hl/A== X-Google-DKIM-Signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=1e100.net; s=20161025; h=x-gm-message-state:mime-version:in-reply-to:references:from:date :message-id:subject:to; bh=rGXbYxFkEc4p0CgaSKTThROj1+2l+YW9iPYjA7HodLI=; b=BNYm+2jbKqf6QQ93dHQw+OMBtuU7wUU23VGPd6wa4meTES1nWLa9ywjw/+5y9ULuZh ITbbidMdIFH7YepSlHUnNz++ELG/SGn9HXl+qC0f+InqrCtWNkNb1zhcBlYs1EpFDGqS rugygY5+3MBNFTfv7LEuoNGoC+VXIO1lVW552EXP6wk7kOP/t3tlLjycyskrxp2HHhv/ KofY5pLd9WgTScDdi4mBhXqy06N/yVLEpkc8nfT7hmSCK91BiA6jiKTDdTaNiQkN8wRy HMU/Xxp4cKuuZQsxNXYkNAX4ql/kL5FLyom1sqGo5LNT7PUR8dLdQShy0bBmyOfX4LLl OvDg== X-Gm-Message-State: APf1xPAbmngF8T+tN7LJbiCWzlQhkAD3LHIXHg2tu/At1FYC6suPUGvI eb9zD4KuMebPKDYGrBaGDGWMUMCuoJLECG+hcMk= X-Google-Smtp-Source: AH8x225V0UwBr0jBz28Jr591bOXXyIKu9fAQsVzty+daIWlydRmNiMXIh2nBq7Ycu+xEUTqzyO87ZvGgV7xVNc8H48s= X-Received: by 10.36.162.13 with SMTP id j13mr3263841itf.74.1518176745040; Fri, 09 Feb 2018 03:45:45 -0800 (PST) MIME-Version: 1.0 In-Reply-To: References: From: "dmn (graahnul DOT grom AT gmail DOT com) [via geda-user AT delorie DOT com]" Date: Fri, 9 Feb 2018 14:45:44 +0300 Message-ID: Subject: Re: [geda-user] Another PCB grid step question To: geda-user AT delorie DOT com Content-Type: text/plain; charset="UTF-8" Reply-To: geda-user AT delorie DOT com Errors-To: nobody AT delorie DOT com X-Mailing-List: geda-user AT delorie DOT com X-Unsubscribes-To: listserv AT delorie DOT com Precedence: bulk On 2/9/18, Richard Rasker (rasker AT linetec DOT nl) [via geda-user AT delorie DOT com] wrote: > Hello, Hello, Richard. > I myself predominantly work in a 0.1 mm or 0.05 mm grid, with occasional > excursions to 0.5 mm. For this reason, I have my step size fixed at 0.05 > mm. If I want to go from 0.1 to 0.5, I have to hit the G key 8 times, or > even 18 times to get at 1 mm (or take the scenic route through the menus). It could be helpful to define a custom menu and add keybindings to quickly switch between favorite grid sizes, for example: {"My Grids" m=g {"0.01 mm" checked=gridsize,0.01mm SetUnits(mm) SetValue(Grid,0.01mm) a={"" "Altz"}} {"0.05 mm" checked=gridsize,0.05mm SetUnits(mm) SetValue(Grid,0.05mm) a={"" "Altx"}} {"0.5 mm" checked=gridsize,0.5mm SetUnits(mm) SetValue(Grid,0.5mm) a={"" "Altc"}} {"1 mm" checked=gridsize,1mm SetUnits(mm) SetValue(Grid,1mm) a={"" "Altv"}} } Regards, Dmitry.