X-Authentication-Warning: delorie.com: mail set sender to geda-user-bounces using -f X-Recipient: geda-user AT delorie DOT com DKIM-Signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=gmail.com; s=20120113; h=mime-version:in-reply-to:references:date:message-id:subject:from:to :content-type; bh=c4slZYNt1EdxrnzI1iKLuo3x2/qEaZwcsjpEmQya7aY=; b=YS4ow7LSqsmF1sDmr8+Xugi7SS8MfkXkliig1kSuoz1okDb50g4Nk2WCvYQvNecD1E dpyGb/k6CWkDRfrSLDsEzkFyTcVyFstapeB59vt3SQ1OwhwLSHDuCXyDQbt2fzzKu/oH bDtF2ZxqBdGqTaUFjKkXQVR5a8Cmi7GTCX3iZVep82dVqL17Re1TYYMPC9/iL1NA2RU7 2e23RFDwp3YwWxNL6+B8168uPZQpgbaC0BZyvxm41ePUf/PfjrjjDlBWKHfdcOVbul0b Kb54qEdce1it82azUVCSJSmEUl+YM8HYLsfjdOoHxP/zBNMNQLwUzL3ZX8E/k0L0Ginm pX4A== MIME-Version: 1.0 X-Received: by 10.58.234.161 with SMTP id uf1mr20757553vec.57.1374859454047; Fri, 26 Jul 2013 10:24:14 -0700 (PDT) In-Reply-To: <201307261708.r6QH8BdA026224@envy.delorie.com> References: <201307261708 DOT r6QH8BdA026224 AT envy DOT delorie DOT com> Date: Fri, 26 Jul 2013 13:24:14 -0400 Message-ID: Subject: Re: [geda-user] PCB doesn't auto-route From: Rob Butts To: geda-user AT delorie DOT com Content-Type: multipart/alternative; boundary=047d7b6d7a9a5fec5d04e26d6959 Reply-To: geda-user AT delorie DOT com Errors-To: nobody AT delorie DOT com X-Mailing-List: geda-user AT delorie DOT com X-Unsubscribes-To: listserv AT delorie DOT com Precedence: bulk --047d7b6d7a9a5fec5d04e26d6959 Content-Type: text/plain; charset=ISO-8859-1 I do have two polygon areas that I added and placed as footprints that are in my pcb-elements file. They do not connect to anything; just shapes that I want to attach metal plates to. Yes, the routed layers are shown. There are 13 nets and none are disabled. The log says "The rats nest is stale! Aborting autoroute..." On Fri, Jul 26, 2013 at 1:08 PM, DJ Delorie wrote: > > Do you have any ground/power polygons you're trying to route through? > Are all the to-be-routed layers shown? Did you do "optimize rats" and > make sure all the nets you want are not "disabled for routing" in the > nets dialog? Are there any messages in the message log? > > --047d7b6d7a9a5fec5d04e26d6959 Content-Type: text/html; charset=ISO-8859-1 Content-Transfer-Encoding: quoted-printable
I do have two polygon areas that I added and placed as foo= tprints that are in my pcb-elements file.=A0 They do not connect to anythin= g; just shapes that I want to attach metal plates to.=A0 Yes, the routed la= yers are shown.=A0 There are 13 nets and none are disabled.=A0 The log says= "The rats nest is stale! Aborting autoroute..."=A0


On Fri,= Jul 26, 2013 at 1:08 PM, DJ Delorie <dj AT delorie DOT com> wrote:

Do you have any ground/power polygons you're trying to route through? Are all the to-be-routed layers shown? =A0Did you do "optimize rats&qu= ot; and
make sure all the nets you want are not "disabled for routing" in= the
nets dialog? =A0Are there any messages in the message log?


--047d7b6d7a9a5fec5d04e26d6959--