X-Authentication-Warning: delorie.com: mail set sender to geda-user-bounces using -f X-Recipient: geda-user AT delorie DOT com DKIM-Signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=gmail.com; s=20120113; h=mime-version:in-reply-to:references:date:message-id:subject:from:to :content-type; bh=fVctScNjCcDbWMAtjkj3MB80/ylR9OINUTI6kLv9DTU=; b=0mQgGkNeFNDCtWAUKExpU+OQqjva763KiLu2g2o7r0B4w2pyOyJdEc5M+p3x54D43V H+5hGs6M4FPb5WLLAbWTPDOI8zqwIxQamhqN0ZvS4/sLeqIv+PijBlCw6Rsreuz0pULP kAohSNkpFASKgVnf97kySw+X+ShCexDgfoIdevm2UHmsaRnGHljB/XSph2qfMOl60mom SIXghrvOh6l2DyihOqzAlFebP3dKA+tLL0heM6CNmQRnAafI7IYGrQdhBg0zB54F0l4N 9gLzZP8qeEaKzopy/gRxPxBOpovaKhiVD0HBwrC6vTG1+erYQZu9rDUyVsQMWsyUWKjV 5jeg== MIME-Version: 1.0 X-Received: by 10.182.108.132 with SMTP id hk4mr4253773obb.14.1369217315113; Wed, 22 May 2013 03:08:35 -0700 (PDT) In-Reply-To: References: Date: Wed, 22 May 2013 14:08:35 +0400 Message-ID: Subject: Re: [geda-user] Re: refdes renumber From: =?KOI8-R?B?4czFy9PFyiDowdLYy8/X08vJyg==?= To: geda-user AT delorie DOT com Content-Type: multipart/alternative; boundary=089e0149d220b0124d04dd4bbff1 Reply-To: geda-user AT delorie DOT com Errors-To: nobody AT delorie DOT com X-Mailing-List: geda-user AT delorie DOT com X-Unsubscribes-To: listserv AT delorie DOT com Precedence: bulk --089e0149d220b0124d04dd4bbff1 Content-Type: text/plain; charset=ISO-8859-1 If you speak about Renumber action in PCB program and backannotte to gschem, yes it possible. But renumber in pcb is not properly from the point of view design documentation. Renumber need to use in schematic document. Therefore need to use external program to replace REFDES attributes in SCH and PCB designs simultaneously. Or patched gschem order to gschem replace REFDES attribute in PCB design. How better? External script for simultaneous renumber SCH and PCB may be existed, but I do not finding. 2013/5/22 Nathan Stewart > Ok, I'm not sure how gschem2pcb could do anything. Renumber within pcb > builds a map of input refdes to output refdes. But in gschem you're just > changing the refdes, which as the name implies is a reference. I think to > do what you're trying to accomplish you should use the renumber command, > and just don't change refdes in gschem once that part has been place in > pcb. Thats why it builds a mapping. > --089e0149d220b0124d04dd4bbff1 Content-Type: text/html; charset=ISO-8859-1 Content-Transfer-Encoding: quoted-printable
If you speak about Renumber action in = PCB program and backannotte to gschem, yes it possible.
But renumb= er in pcb is not properly from the point of view design documentation.
Renumber need to use in schematic document.
Therefore = need to use external program to replace REFDES attributes in SCH and PCB d= esigns s= imultaneously.
Or patched gschem
order to gschem replace REFDES attribute in PCB= design.
How better?

External script for =
simultan= eous renumber SCH and PCB may be existed, but I do not finding.



2= 013/5/22 Nathan Stewart <therealnathanstewart AT gmail DOT com&g= t;

Ok, I'm not sure how gschem2pcb could= do anything. Renumber within pcb builds a map of input refdes to output re= fdes.=A0 But in gschem you're just changing the refdes, which as the na= me implies is a reference.=A0 I think to do what you're trying to accom= plish you should use the renumber command, and just don't change refdes= in gschem once that part has been place in pcb. Thats why it builds a mapp= ing.


--089e0149d220b0124d04dd4bbff1--