X-Authentication-Warning: delorie.com: mail set sender to geda-user-bounces using -f X-Recipient: geda-user AT delorie DOT com DKIM-Signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=gmail.com; s=20120113; h=mime-version:in-reply-to:references:date:message-id:subject:from:to :content-type; bh=76KoWbZxwvzITtx8baDqtoB1xQDNMSqv2Vg4m5ovMQI=; b=zh2YU+JTijiSQRMCSpLl0xE5uxFXnlMsOkgEa2BWT2iohfiwMkqByi8eKfeotbPBJD 84aLHLD636nHuCNHUujSxxpVfEvWS6J2F3M8nOZ/XsGj4DSp82XAIksCuwnaleIZbj2s OjEcNzx9qxM2JE+IT+q6CTscgQRHCXkqmah9lgatT6mLUhsVbOg8o+oMD6HO4vxlbA/1 AV53ywvcfkkjIpEa7cATQga1X/8OoSof88BjYG9Y8CqCVrufUXgLHR1MtPy7LAVWCmjX GENBx130vKlyOECWfJ7pIBOsoQ7xhPztw+p4icg7xwnZjq/7MKvXaM81G/XEr+ArhBin z3bQ== MIME-Version: 1.0 In-Reply-To: <20121204183305.6b04c0dc@jive.levalinux.org> References: <20121204183305 DOT 6b04c0dc AT jive DOT levalinux DOT org> Date: Fri, 14 Dec 2012 10:29:18 +0100 Message-ID: Subject: Re: [geda-user] Find rat lines From: Levente To: gEDA User Mailing List Content-Type: multipart/alternative; boundary=e89a8fb2058e74198604d0ccaa86 Reply-To: geda-user AT delorie DOT com Errors-To: nobody AT delorie DOT com X-Mailing-List: geda-user AT delorie DOT com X-Unsubscribes-To: listserv AT delorie DOT com Precedence: bulk --e89a8fb2058e74198604d0ccaa86 Content-Type: text/plain; charset=ISO-8859-1 Okay.... I lost track of this thread, but I have an idea. I've seen this implementation in Zuzken CR5000 Board designer. Each copper object had an attribute called "net". When you place a track you could click on an object to connect to. This way, there is no need to do any graphs, etc. Just compare touching copper objects net attribute. If it is not the same emit warning. Just my HUF 100 On Tue, Dec 4, 2012 at 6:33 PM, Levente Kovacs wrote: > Hi all, > > > I experience that in recent PCB (git HEAD) pressing the F key doesn't > highlight the unrouted rat lines. > > Does anyone else experience this? > > Thanks, > Levente > > -- > Levente Kovacs > CTO, CSO > http://levente.logonex.eu > > --e89a8fb2058e74198604d0ccaa86 Content-Type: text/html; charset=ISO-8859-1 Content-Transfer-Encoding: quoted-printable Okay....


I lost track of this thread, but I have an idea. I'= ve seen this implementation in Zuzken CR5000 Board designer. Each copper ob= ject had an attribute called "net". When you place a track you co= uld click on an object to connect to. This way, there is no need to do any = graphs, etc. Just compare touching copper objects net attribute. If it is n= ot the same emit warning.


Just my HUF 100

On Tue, Dec 4, 20= 12 at 6:33 PM, Levente Kovacs <leventelist AT gmail DOT com> wr= ote:
Hi all,


I experience that in recent PCB (git HEAD) pressing the F key doesn't highlight the unrouted rat lines.

Does anyone else experience this?

Thanks,
Levente

--
Levente Kovacs
CTO, CSO
http://levente.logo= nex.eu


--e89a8fb2058e74198604d0ccaa86--