X-Authentication-Warning: delorie.com: mail set sender to geda-user-bounces using -f Date: Wed, 25 Jul 2012 17:34:16 -0400 Message-Id: <201207252134.q6PLYGZs029412@envy.delorie.com> From: DJ Delorie To: geda-user AT delorie DOT com In-reply-to: (message from Ram Bhamidipaty on Wed, 25 Jul 2012 14:29:55 -0700) Subject: Re: [geda-user] how to use "clearance" and mask in pcb footprint References: <5010D52B DOT 8030800 AT plastitar DOT com> <5010F048 DOT 3010304 AT plastitar DOT com> Reply-To: geda-user AT delorie DOT com Typical numbers are 8-10 mil copper clearance and 3 mil mask clearance. "Clearance" is the distance between the two. A 40 mil diameter copper pad with 3 mil mask clearance means the mask hole will be 46 mil diameter. http://www.delorie.com/pcb/docs/gs/gs.html#Terminology