X-Authentication-Warning: delorie.com: mail set sender to geda-help-bounces using -f X-Recipient: geda-help AT delorie DOT com X-Original-DKIM-Signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=gmail.com; s=20120113; h=mime-version:in-reply-to:references:from:date:message-id:subject:to; bh=bbxIT9jzZvGLsKiN0Kli9RMc/0rLt0luGzmOLPgBd6E=; b=hm4xAyJxd1Y7SUeVBN36OUaJ7rY/Ss/sKiKtD5XdZ3cpppfRSifzKkstd7sJwhDbPD fBubaJ40l9w7rNWiJOOQezapV4CSTf8QACocbdk2Il7kkhQCfk0CK0+pHs1V7upXFvVR h2U0No0n76bKpnen18DCpMJNpG/zQ8T4Kd8vMWTzgDoubDpzowEEuK05eM/gxzkAu+Qf 5gUtzDZdttAr8soMGblbYlSIR1f7qtNYsvPkWwSRq3kd79Sc4yvcTQFeNmo5yg2Ni3BN pL/0psjjnjPiDAG+3jh+FOVDx2aYrtxsSKCXEf2D3X1B0Kp/39EnuzXH9DB88grM33bt wGVw== X-Google-DKIM-Signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=1e100.net; s=20130820; h=x-gm-message-state:mime-version:in-reply-to:references:from:date :message-id:subject:to; bh=bbxIT9jzZvGLsKiN0Kli9RMc/0rLt0luGzmOLPgBd6E=; b=BPwte51uh/5NrPe6waC/l1WFge14GABnoRO9UHEKxVJ88n9lFZ71+9pYt+gGh1g8PQ H+V9/WbyehjRteoQKSHitT7/xcvx2MnS+XrWQ+V5zbwMQzXGNGvyGupMXE3uQAHdBrQ0 J4+4xoiGPoFdgCQNfvNOBSxhMCzj6EzeFKWx9SU1K6XXfOETfktO0DJSEXnbghRMheXH GPM2yiYtERhkbMon1u7uHwaT+AoR8NG+y6oxqdYenieSjLxfRgK0UUq2uJRKmWWSmDat lXziv+VEPyIInYq+woKyX0YC3Qc8VcuY9w853C5EiYA3UItwIgjxHCbMF8+OLe9v8GpB RDRw== X-Gm-Message-State: AD7BkJI6TaFhllMhDsh+Zqq4hrOg0UPXoev3gTdWxYZ1qBl5260GLm+gMyQMzpWtUFVb0yJbympxeCRjcl7r9A== X-Received: by 10.50.183.5 with SMTP id ei5mr1054058igc.79.1457724894736; Fri, 11 Mar 2016 11:34:54 -0800 (PST) MIME-Version: 1.0 In-Reply-To: References: <416A6868-9BE3-48F2-A356-B6BCD09F6B37 AT wellesley DOT edu> <201603102216 DOT u2AMGD4F027126 AT envy DOT delorie DOT com> From: "Mike Bushroe (mbushroe AT gmail DOT com) [via geda-help AT delorie DOT com]" Date: Fri, 11 Mar 2016 12:34:25 -0700 Message-ID: Subject: Re: [geda-help] Copper connection in pcb between different nets in gschem To: geda-help AT delorie DOT com Content-Type: multipart/alternative; boundary=001a11c39e7287f7df052dcb062a Reply-To: geda-help AT delorie DOT com Errors-To: nobody AT delorie DOT com X-Mailing-List: geda-help AT delorie DOT com X-Unsubscribes-To: listserv AT delorie DOT com Precedence: bulk --001a11c39e7287f7df052dcb062a Content-Type: text/plain; charset=UTF-8 Content-Transfer-Encoding: quoted-printable What about using a through hole jumper to perform the same function as the zero ohm SMD when the planes are on the surface? Assuming you have some freedom to place the cross connect anywhere along their boarder you should be able to find two spots for the through holes. I don't know if that would change the cost of manufacturing an otherwise all SMD board with only layer to layer vias, but I would think the process for making a top to bottom via would also make plated through holes. I just know that setting up something I just HAVE to do on the very last run before submitting is a surefire recipe for disaster for me. I would rather put up with seeing the short every time I rand DRC than risk sending the files off to hastily. Mike On Fri, Mar 11, 2016 at 12:20 PM, Peter Clifton ( petercjclifton AT googlemail DOT com) [via geda-help AT delorie DOT com] < geda-help AT delorie DOT com> wrote: > (And be CAREFUL)... I've missed nets because of this. Be sure to make the > short at the last possible moment. > > Peter > > On 10 March 2016 at 22:16, DJ Delorie wrote: > >> >> There's no change since forever for this, it's been the same all along >> - you have to manually short the two grounds as the last step in >> layout, and ignore the DRC errors for those grounds after that. >> > > --=20 "Creativity is intelligence having fun." =E2=80=94 Albert Einstein --001a11c39e7287f7df052dcb062a Content-Type: text/html; charset=UTF-8 Content-Transfer-Encoding: quoted-printable
What about using a through hole jumper to perform the same= function as the zero ohm SMD when the planes are on the surface? Assuming = you have some freedom to place the cross connect anywhere along their board= er you should be able to find two spots for the through holes. I don't = know if that would change the cost of manufacturing an otherwise all SMD bo= ard with only layer to layer vias, but I would think the process for making= a top to bottom via would also make plated through holes.

=C2=A0 I just know that setting up something I just HAVE to do on the ve= ry last run before submitting is a surefire recipe for disaster for me. I w= ould rather put up with seeing the short every time I rand DRC than risk se= nding the files off to hastily.


Mik= e

On F= ri, Mar 11, 2016 at 12:20 PM, Peter Clifton (petercjclifton AT googlemail DOT com) [via geda-help AT delorie DOT com] <<= a href=3D"mailto:geda-help AT delorie DOT com" target=3D"_blank">geda-help AT delorie= .com> wrote:
(And be CAREFUL)... I've missed nets because of this. Be sure t= o make the short at the last possible moment.

Peter
<= div class=3D"gmail_extra">
On 10 March 2016 a= t 22:16, DJ Delorie <dj AT delorie DOT com> wrote:

There's no change since forever for this, it's been the same all al= ong
- you have to manually short the two grounds as the last step in
layout, and ignore the DRC errors for those grounds after that.




--
"Creativity is intelligence having fun." = =E2=80=94 Albert Einstein