delorie.com/archives/browse.cgi | search |
X-Authentication-Warning: | delorie.com: mail set sender to geda-user-bounces using -f |
X-Recipient: | geda-user AT delorie DOT com |
DKIM-Signature: | v=1; a=rsa-sha256; c=relaxed/relaxed; |
d=gmail.com; s=20120113; | |
h=mime-version:in-reply-to:references:date:message-id:subject:from:to | |
:content-type; | |
bh=TKlsgXEsZ/NCN+c4lu++mP5Ol+g/dwz9Gr6KH5Zm9/c=; | |
b=J3+Ia7mtJmjDWjjvSkHY5QY1rK7Sdlq4Wd/EpGCZQX6244u5Vjs6U+6+Zs9Bloj4Hm | |
2Dgisgcr6GWA2sWhPSirzq0u0sFALvVmDQfCuYOlmwozw1UCkaRRYKtalSIQBbJTrH6q | |
uatzHsMDs4+5krNb/ujZlY2drpArEqW31iZ4/qXTWz8tPcY6KGR6cOeunB265CWUM9IL | |
jT7NgrmQP7E2hpY0k3RJSouMK+Lf2ib9jhNyabm+ndUbMTBtPeNHKToTx2X770MpChiu | |
ehNgPdB8FPk2OSQRgHI7J/DmO5CaWzwS+DyjplM7ibAKoP5wOBxsXWJwUXuRi3wpJRqo | |
2Bxw== | |
MIME-Version: | 1.0 |
X-Received: | by 10.52.74.161 with SMTP id u1mr24489469vdv.72.1429654372943; |
Tue, 21 Apr 2015 15:12:52 -0700 (PDT) | |
In-Reply-To: | <5536A38F.50104@m0n5t3r.info> |
References: | <CALSZ9goH9CUT=5DStdVUG4d45ff30WieHc2-DsXpjX=7cf42Nw AT mail DOT gmail DOT com> |
<5536A38F DOT 50104 AT m0n5t3r DOT info> | |
Date: | Tue, 21 Apr 2015 18:12:52 -0400 |
Message-ID: | <CALSZ9gpoqcOxNRDvwEHipCgkHq0z+KmPY2AWBdRC_DRnz5SD+w@mail.gmail.com> |
Subject: | Re: [geda-user] Stepper driver issues |
From: | Rob Butts <r DOT butts2 AT gmail DOT com> |
To: | geda-user AT delorie DOT com |
Reply-To: | geda-user AT delorie DOT com |
Errors-To: | nobody AT delorie DOT com |
X-Mailing-List: | geda-user AT delorie DOT com |
X-Unsubscribes-To: | listserv AT delorie DOT com |
--bcaec5015da90d0abd051443593b Content-Type: text/plain; charset=UTF-8 Content-Transfer-Encoding: quoted-printable * Can you spin the rotor by hand when it's disconnected? All three steppers spin freely. * Have you checked winding continuity? They all measure close to 4 ohms * Are the windings connected properly? I have a connector to the stepper with colored wires to each winding (a+ - green, a- - blue, b+ - black, b- - red). Yes, they are verified connected to the correct pin (1st, 3rd, 4th and 6th) respectively. As for trying the steppers with a 12V supply, I haven't gotten help for that yet. =E2=80=8B --bcaec5015da90d0abd051443593b Content-Type: text/html; charset=UTF-8 Content-Transfer-Encoding: quoted-printable <div dir=3D"ltr"><div><div>* Can you spin the rotor by hand when it's d= isconnected? <br><br>All three steppers spin freely.<br><br>* Have you chec= ked winding continuity?<br><br></div><div>They all measure close to 4 ohms<= br><br>* Are the windings connected properly?<br><br></div>I have a connect= or to the stepper with colored wires to each winding (a+ - green, a- - blue= , b+ - black, b- - red).=C2=A0 Yes, they are verified connected to the corr= ect pin (1st, 3rd, 4th and 6th) respectively.<br><br></div>As for trying th= e steppers with a 12V supply, I haven't gotten help for that yet.<br><d= iv>=E2=80=8B</div></div> --bcaec5015da90d0abd051443593b--