On Fri, 28 May 2021, Roland Lutz wrote:
> On Fri, 28 May 2021, karl AT aspodata DOT se [via geda-user AT delorie DOT com] wrote:
>> Now, theese sets of messages comes as a group when e.g. moving the
>> mouse pointer from outside to the inside of the gschem window and
>> reverse, but not if I first click in e.g. the message window.
>>
>> Ditto, switching virtual displays, virtual terminal, and when
>> clicking inside various parts of gschem like alternativly
>> clicking in docks and main (canvas) window.
>
> This looks like the messages appear whenever the page is rendered, which
> would indicate that the invalid objects are part of the page (as opposed
> to some invalid intermediate state while loading/closing the page).
I can't say for sure with the information I have, but the most probable
cause for this seems to be an invalid fill type field in a file. I pushed
a patch which adds a check for line and fill types. You should now see a
message in the status window whenever gschem occurs an invalid value.