Mail Archives: geda-user/2019/12/17/16:49:05
Nicklas Karlsson:
> > On Mon, 16 Dec 2019 22:28:09 +0100
> > "N (nicklas DOT karlsson17 AT gmail DOT com) [via geda-user AT delorie DOT com]"
> > <geda-user AT delorie DOT com> wrote:
> >
> > > In hierachical schematics it seems pins/refdes with small letters are
> > > ignored. It works with gsch2pcb but with lepton-sch2pcb these seems
> > > to be ignored.
> > >
> > > Prefer to use both capital and small letters though it is not very
> > > important but make them simply disappear without complaint I consider
> > > bad.
The difference I see betweeb gsch2pcb (gEDA 1.9.2 (g7b0ee03)) and
lepton-sch2pcb (Lepton EDA 1.9.9 (git: 7ce80ce)) is different
unnamed_net numbers and that the net symbols shows up unnessesary in
lepton. Names like (in .net file) 5Rb1-2 rsU1-10 works without any
problem in my hierarchical schematics.
> > Attribute's value may contain uppercase and/or lowercase letters,
> > there are no restrictions on that. I use both, too, and lepton-sch2pcb
> > works fine for me. Could you please provide more information on the
> > issue (test schematics, commands used, program's output,
> > configuration files, etc.)?
> > And do not hesitate to use the issue tracker on github
> > (https://github.com/lepton-eda/lepton-eda/issues) and gitter.im chat
> > (https://gitter.im/Lepton-EDA/Lobby) if you have any problems or
> > questions.
...
As previous responder asked you, provide test files, we don't see your
problem, and unless you do so, we cannot help you.
Regards,
/Karl Hammar