delorie.com/archives/browse.cgi   search  
Mail Archives: geda-user/2018/08/06/07:10:51

X-Authentication-Warning: delorie.com: mail set sender to geda-user-bounces using -f
X-Recipient: geda-user AT delorie DOT com
Date: Mon, 6 Aug 2018 13:09:40 +0200 (CEST)
From: Roland Lutz <rlutz AT hedmen DOT org>
To: "Rob Butts (r DOT butts2 AT gmail DOT com) [via geda-user AT delorie DOT com]" <geda-user AT delorie DOT com>
Subject: Re: [geda-user] No GND net in pcb
In-Reply-To: <CALSZ9gofHFayYE4sGEJsj2A0ZccY8Eihka49TEphm-riuUFVkg@mail.gmail.com>
Message-ID: <alpine.DEB.2.20.1808061303030.3881@nimbus>
References: <CALSZ9gofHFayYE4sGEJsj2A0ZccY8Eihka49TEphm-riuUFVkg AT mail DOT gmail DOT com>
User-Agent: Alpine 2.20 (DEB 67 2015-01-07)
MIME-Version: 1.0
Reply-To: geda-user AT delorie DOT com
Errors-To: nobody AT delorie DOT com
X-Mailing-List: geda-user AT delorie DOT com
X-Unsubscribes-To: listserv AT delorie DOT com

  This message is in MIME format.  The first part should be readable text,
  while the remaining parts are likely unreadable without MIME-aware tools.

--8323329-1830666611-1533553780=:3881
Content-Type: text/plain; charset=UTF-8; format=flowed
Content-Transfer-Encoding: 8BIT

On Sat, 4 Aug 2018, Rob Butts (r DOT butts2 AT gmail DOT com) [via 
geda-user AT delorie DOT com] wrote:
> I created a simple 1 page schematic then did the gsch2pcb -v but the 
> netlister is not getting the GND net.  I tried adding the net=GND:1 to a 
> thruhole but I'm still not getting the GND net in pcb.
> 
> All of the GND symbols in my schematic have the net=GND:1 attribute.

What do you mean with "the netlister is not getting the GND net"?

In PCB, you can go to Window -> Netlist to see what nets have been 
reported by gnetlist.

> How can I see what the netlister is putting out?

As Dmitry already pointed out, you can do

$ gnetlist -o - -g pcbfwd page1.sch page2.sch ...

from the directory in which your schematics live to see the raw netlister 
output.  (Please note that the backend used by "Import Schematics" is 
called "pcbfwd", not "PCB", and that it may be necessary to add a "-L 
/.../share/gEDA/scheme/" option if you installed PCB to a nonstandard 
location.)