Subject: [geda-user] shorted pads and the netlist in PCB
Openpgp: preference=signencrypt
Autocrypt: addr=mcguire AT neurotica DOT com; prefer-encrypt=mutual; keydata=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Message-ID: <04df2ed2-45a1-dff5-6f6c-d9b9d5fcca0f@neurotica.com>
Date: Tue, 10 Jul 2018 14:15:11 -0400
User-Agent: Mozilla/5.0 (X11; Linux x86_64; rv:52.0) Gecko/20100101
Thunderbird/52.8.0
MIME-Version: 1.0
Reply-To: geda-user AT delorie DOT com

  Hey folks.  This has been bugging me off-and-on for years, and since I
just ran across it again I thought I'd ask about it.

  When I have, for example, a surface-mount voltage regulator that has
an exposed pad that's connected to ground, and I connect it to a plane
for thermal reasons, I get complaints in the PCB Log window about the
net that's connected to the plane being shorted to that pin of the
component, because it's not reflected in the schematic (which may not
have a "pin" for that pin) and is thus not in the generated netlist.

  Is there a way to deal with that gracefully, rather than just ignoring
the error messages in the log?  Surely others have run across this.