delorie.com/archives/browse.cgi   search  
Mail Archives: geda-user/2018/02/16/09:51:18

X-Authentication-Warning: delorie.com: mail set sender to geda-user-bounces using -f
X-Recipient: geda-user AT delorie DOT com
Subject: Re: [geda-user] (Off-topic) Question wrt driving HV piezo transducer
To: geda-user AT delorie DOT com
References: <c3aa1897-3806-3f72-feef-85551a63c2db AT linetec DOT nl>
<alpine DOT DEB DOT 2 DOT 00 DOT 1802091235090 DOT 12270 AT igor2priv>
<6221de93-bb98-d397-79b4-eecf3975c2e6 AT linetec DOT nl>
<alpine DOT DEB DOT 2 DOT 00 DOT 1802091324350 DOT 12270 AT igor2priv>
<f2259553-7015-8fc8-33b2-8ca8be6c5a45 AT linetec DOT nl>
<alpine DOT DEB DOT 2 DOT 00 DOT 1802091427450 DOT 12270 AT igor2priv>
<20180209161532 DOT 6AF57804CEFA AT turkos DOT aspodata DOT se>
<alpine DOT DEB DOT 2 DOT 00 DOT 1802091735590 DOT 12270 AT igor2priv>
<20180209204934 DOT CAA35804CEFA AT turkos DOT aspodata DOT se>
<alpine DOT DEB DOT 2 DOT 00 DOT 1802100406500 DOT 12270 AT igor2priv>
<b125c1d5-48a1-c1dc-3ee1-db9875d50bf6 AT linetec DOT nl>
<c49d734f1b1f6373733e6f9935afff35 AT iae DOT nl>
<da435a2d-0bd0-f6d7-7d9a-05394665621c AT linetec DOT nl>
<aeedf5b6a230f39abdc82845a57a8b1b AT iae DOT nl>
<1a5665d2-c032-29f3-6de3-d4e3cd52f42b AT linetec DOT nl>
From: "John Griessen (john AT ecosensory DOT com) [via geda-user AT delorie DOT com]" <geda-user AT delorie DOT com>
Message-ID: <b097cf74-952e-76a9-2c6e-f3642c21292a@ecosensory.com>
Date: Fri, 16 Feb 2018 08:49:55 -0600
User-Agent: Mozilla/5.0 (X11; Linux x86_64; rv:52.0) Gecko/20100101
Thunderbird/52.6.0
MIME-Version: 1.0
In-Reply-To: <1a5665d2-c032-29f3-6de3-d4e3cd52f42b@linetec.nl>
Reply-To: geda-user AT delorie DOT com
Errors-To: nobody AT delorie DOT com
X-Mailing-List: geda-user AT delorie DOT com
X-Unsubscribes-To: listserv AT delorie DOT com

On 02/16/2018 05:38 AM, Richard Rasker (rasker AT linetec DOT nl) [via geda-user AT delorie DOT com] wrote:
> I'd better start calculating, building and measuring things now.

That's how to do transformers.   Iterate and test.

Push pull avoids saturation, requires custom parts.

If you want a flyback inductor system, you still have to keep outflow/inflow balanced or saturation.
So simple single ended PWM doesn't work unless it is low duty cycle so the inflow is always a good bit less than the outflow.

-- 
John Griessen -- building lab gear for biologists