delorie.com/archives/browse.cgi   search  
Mail Archives: geda-user/2017/08/12/14:54:11

X-Authentication-Warning: delorie.com: mail set sender to geda-user-bounces using -f
X-Recipient: geda-user AT delorie DOT com
X-Original-DKIM-Signature: v=1; a=rsa-sha256; c=relaxed/relaxed;
d=gmail.com; s=20161025;
h=mime-version:in-reply-to:references:from:date:message-id:subject:to;
bh=ByAdhmm9rItgCS5uvkrKzApJBFGsyZDr6EPHyRba19Q=;
b=dcO+uatcPyJ3Ihm08b3ziXSUaF0ZY8Ci64Hb2m90mTeS9sx3mF3A75PqgxHgc8InXG
wKUlkVpvzy6IFe+RaLbmdRWFvPPCf/QKES6zt4z/jw18Fc5A2ISBpHgrbKd0p/NoEyhv
qUUE05rBQD87kmOzZ/FumrsCg9ho3TC8Awt1s6PYjvPCrge8kgFwdMmuVGxhkbVFq8au
QKlz7IRcY8IOgyn+FWqGzAz+eiNHGW5rXGHV2afqboFZY1YW2+46kI/wOPQqAXLoL2se
sn2b3zNWDozqej1fN9e0dVgv1HY6d+5Emi/PmBWdLzLTnUj3YH/fXrnoxyZAvYgQPRMu
D6Lg==
X-Google-DKIM-Signature: v=1; a=rsa-sha256; c=relaxed/relaxed;
d=1e100.net; s=20161025;
h=x-gm-message-state:mime-version:in-reply-to:references:from:date
:message-id:subject:to;
bh=ByAdhmm9rItgCS5uvkrKzApJBFGsyZDr6EPHyRba19Q=;
b=ptRJ6zb3eNDmPW9Vhlh2nHDHEcBZoQb6NJq45CeENy92L0wOzrs6hDM0dCvOHaaGOZ
vEH/kR4VH0GO2L6nVRiqqFAfJlCX/zEFLnPIqkS5rg+Q6voifu8FYXf9HdecBylYVrj0
U/0xfvONBDfv0MjlmhVZi7QFOcHr1f226Sy7h7P01totzkC6dGzEcUL4kCmoBp8/Ytk/
TAv2Z3XABCM342HuDpJNZ60I6GFRJu3KPPhN+vvJeAGz53hNRiqm+8E7LbrghDHwTEYi
1NojRWg2FvBF+QvH6B5X1vfZDLVovFpEk/TF8CVPFUh0uqejjusEOdKUEEjDAqS29+e3
oR+A==
X-Gm-Message-State: AHYfb5gwyjAKGXhK4lP2+Jb76VGX4hug+WoogRSZedXBMyPlQ9D2t4Zn
7vX9l7wHEKGaUDYl2CTvD7zm3b0FNg==
X-Received: by 10.31.69.8 with SMTP id s8mr12630950vka.102.1502563913497; Sat,
12 Aug 2017 11:51:53 -0700 (PDT)
MIME-Version: 1.0
In-Reply-To: <alpine.DEB.2.00.1708122022160.27212@igor2priv>
References: <CALSZ9greJFrL=dBWNUo3NS68Jq=B=C7nLO4FDB+vowa2B1DjwQ AT mail DOT gmail DOT com>
<15585a1f-79e3-3aa2-3f9e-239365b53bed AT ecosensory DOT com> <CALSZ9gqJkoHXW8SazY_7S3k66tapTgMbFgmqCE=uWqf_yfR4cw AT mail DOT gmail DOT com>
<alpine DOT DEB DOT 2 DOT 00 DOT 1708122022160 DOT 27212 AT igor2priv>
From: "Rob Butts (r DOT butts2 AT gmail DOT com) [via geda-user AT delorie DOT com]" <geda-user AT delorie DOT com>
Date: Sat, 12 Aug 2017 14:51:53 -0400
Message-ID: <CALSZ9goqDm9S1+m2z8cx7v-NzjKk2Bu9SuNhFpK65u5d3PDoEQ@mail.gmail.com>
Subject: Re: [geda-user] pcb slotted holes for relay
To: geda-user AT delorie DOT com
Reply-To: geda-user AT delorie DOT com
Errors-To: nobody AT delorie DOT com
X-Mailing-List: geda-user AT delorie DOT com
X-Unsubscribes-To: listserv AT delorie DOT com

--001a114daf8a510217055692ecd5
Content-Type: text/plain; charset="UTF-8"
Content-Transfer-Encoding: quoted-printable

So the footprints are actually created by hand (manually placing copper)
for each pin of the relay?  And the schematic will have the symbol with
pins but the netlist will have unconnected signals that I'll have to ignore=
?

I'm using 10 of these relays.  This sounds extremely cumbersome not to
mention error prone.
=E2=80=8B

--001a114daf8a510217055692ecd5
Content-Type: text/html; charset="UTF-8"
Content-Transfer-Encoding: quoted-printable

<div dir=3D"ltr"><div>So the footprints are actually created by hand (manua=
lly placing copper) for each pin of the relay?=C2=A0 And the schematic will=
 have the symbol with pins but the netlist will have unconnected signals th=
at I&#39;ll have to ignore?<br><br></div>I&#39;m using 10 of these relays.=
=C2=A0 This sounds extremely cumbersome not to mention error prone. <br>=E2=
=80=8B</div>