| delorie.com/archives/browse.cgi | search |
| X-Authentication-Warning: | delorie.com: mail set sender to geda-user-bounces using -f |
| Date: | Sun, 28 Aug 2016 16:23:10 -0400 |
| Message-Id: | <201608282023.u7SKNAee023469@envy.delorie.com> |
| From: | DJ Delorie <dj AT delorie DOT com> |
| To: | geda-user AT delorie DOT com |
| In-reply-to: | <20160828204931.28c4cb373d010473ed5d0bc0@gmail.com> |
| (geda-user AT delorie DOT com) | |
| Subject: | Re: [geda-user] PCB netlist bug, missing connection |
| References: | <20160828204931 DOT 28c4cb373d010473ed5d0bc0 AT gmail DOT com> |
| Reply-To: | geda-user AT delorie DOT com |
| Errors-To: | nobody AT delorie DOT com |
| X-Mailing-List: | geda-user AT delorie DOT com |
| X-Unsubscribes-To: | listserv AT delorie DOT com |
Not a bug. Trailing lower case letters are considered gate letters (slots), and ignored by PCB. For example, you might have a quad NAND gate with refdes U1a, U1b, U1c, and U1d. So your "Cout" looks like "C" to PCB.