delorie.com/archives/browse.cgi | search |
X-Authentication-Warning: | delorie.com: mail set sender to geda-user-bounces using -f |
X-Recipient: | geda-user AT delorie DOT com |
X-Original-DKIM-Signature: | v=1; a=rsa-sha256; c=relaxed/relaxed; |
d=googlemail.com; s=20120113; | |
h=mime-version:in-reply-to:references:date:message-id:subject:from:to | |
:content-type; | |
bh=Wr8d6i/aqnv+Uddboj5nAXa4dAn5mtEL7YEAtDwBgDQ=; | |
b=dHtI9sQ+vefhWH5fKKKHfgT414SFSkPClXKu4GxNZoArfUyAzu0xXXugxIvlIFSsDG | |
z6lN4TlEm9W1ZnNNqMrRehJ5YPyy+DhtMQCq/qN6lH/cohHjM1do9LT91raJHyPjwQCj | |
rjTKJNAVUd+H4MW9p02zW8rGnJgyffttCisuaVEXv5gPsRnWlGzGLqT2nZVQMdfBfC1Y | |
vcEnuweGRwe0WOwwSyrYUQYD7F0XtDOsNtHCu5V8PIg7KQhmwPGZ9sxR5zXuRCUbSgys | |
VTUqAgHp8E+aFKheBwrkU6mr7LFH3ZkVchCr+MyiTkvYyDSY8CYGihLFiEmYUKh5jRXA | |
znug== | |
X-Google-DKIM-Signature: | v=1; a=rsa-sha256; c=relaxed/relaxed; |
d=1e100.net; s=20130820; | |
h=x-gm-message-state:mime-version:in-reply-to:references:date | |
:message-id:subject:from:to:content-type; | |
bh=Wr8d6i/aqnv+Uddboj5nAXa4dAn5mtEL7YEAtDwBgDQ=; | |
b=nIcWw+jYh0fWmkys0yWJ9N7c5t05r7Zx2QzbTaYwUxKnRLFxIW1HRmwRyZhvk9OWCm | |
GObSjPOY7NP4E8EsHRwi9Qi1YE+YgDD1Che4ULMayilfv04IjhbRH2ivsHnrw/OsVxBQ | |
S/62UuvHtVJv15jSqTzKlINkfAn8hGAqyvHq+v9UhYW73GmRsMvnhMP36nmgj4NcGBEM | |
BvvkXF6BKGktGgN8180mjphu46g5JeWr7RnhXpAekb6Q/DxhyFEKmdKST8DlN2JEMFo7 | |
gDipG40LDCDuyZ4h2alV+fQA6AWksiQExyzDJ4ehYkiNUolnyO5ptx3MrnnWhZ9RHODJ | |
ltng== | |
X-Gm-Message-State: | AG10YORih0G5bvaYxvoG3eb6wuELtjL8QXbPmSTMeMn/N1cXiLdy2/ibLJQgF/yHg8af79ox7+BCEKFYw7yQGw== |
MIME-Version: | 1.0 |
X-Received: | by 10.60.35.163 with SMTP id i3mr914878oej.27.1455712237544; Wed, |
17 Feb 2016 04:30:37 -0800 (PST) | |
In-Reply-To: | <56C43FA3.4090904@envinsci.co.uk> |
References: | <56C43FA3 DOT 4090904 AT envinsci DOT co DOT uk> |
Date: | Wed, 17 Feb 2016 12:30:37 +0000 |
Message-ID: | <CAJXU7q8zkh_JWU3C3KOB73iK84PYXf-L4Hoq640dPYg7MQirWA@mail.gmail.com> |
Subject: | Re: [geda-user] settings file for pcb? |
From: | "Peter Clifton (petercjclifton AT googlemail DOT com) [via geda-user AT delorie DOT com]" <geda-user AT delorie DOT com> |
To: | gEDA User Mailing List <geda-user AT delorie DOT com> |
Reply-To: | geda-user AT delorie DOT com |
Errors-To: | nobody AT delorie DOT com |
X-Mailing-List: | geda-user AT delorie DOT com |
X-Unsubscribes-To: | listserv AT delorie DOT com |
--089e0118427ad0717f052bf66afc Content-Type: text/plain; charset=UTF-8 ~/.pcb/preferences contains DRC vaules.. Looking on my system, it appears there may be some breakage though... min-width = 1 px min-silk = 1 px min-drill = 15.00 mil min-ring = 10.00 mil Hmm - what has pixels got to do with anything... BUG? (it gets read in as 0.1mil .actually, but emitting px is wrong) Anyway - try editing that file.. see if it updates things. Be aware that some preferences are saved between PCB runs (but a quick check suggests these DRC clearances are not updated in the file, so should persist once you edit the file). If you create a new design with the old gsch2pcb flow, the defaults it starts with come from a hard-coded template PCB file in the netlister back-end, but as you specifically said "new instance of pcb", I assume you're actually just starting a fresh copy of pcb with no design loaded. (And perhaps using the import schematics functionality to create your new design?) Peter On 17 February 2016 at 09:38, Matt Rhys-Roberts ( matt DOT rhys-roberts AT envinsci DOT co DOT uk) [via geda-user AT delorie DOT com] < geda-user AT delorie DOT com> wrote: > I'm trying to pre-set the default DRC settings on my old version of pcb > (20110918 Compiled on Jul 2 2013 at 11:26:16). > > There is nothing I can do to make pcb remember any kind of DRC settings > from project to project. What you tell me should work, doesn't. > > Please can anyone tell me what settings/config file to create or edit, so > that every time I open a new instance of pcb, the DRC settings are just > there? Or doesn't it work that way? > > Kind regards, > Matt. > --089e0118427ad0717f052bf66afc Content-Type: text/html; charset=UTF-8 Content-Transfer-Encoding: quoted-printable <div dir=3D"ltr"><div><div><div><div><div><div>~/.pcb/preferences contains = DRC vaules..<br><br></div>Looking on my system, it appears there may be som= e breakage though...<br><br>min-width =3D 1 px<br>min-silk =3D 1 px<br>min-= drill =3D 15.00 mil<br>min-ring =3D 10.00 mil<br><br></div>Hmm - what has p= ixels got to do with anything... BUG? (it gets read in as 0.1mil .actually,= but emitting px is wrong)<br><br></div>Anyway - try editing that file.. se= e if it updates things.<br><br></div>Be aware that some preferences are sav= ed between PCB runs (but a quick check suggests these DRC clearances are no= t updated in the file, so should persist once you edit the file).<br><br></= div>If you create a new design with the old gsch2pcb flow, the defaults it = starts with come from a hard-coded template PCB file in the netlister back-= end, but as you specifically said "new instance of pcb", I assume= you're actually just starting a fresh copy of pcb with no design loade= d. (And perhaps using the import schematics functionality to create your ne= w design?)<br><br></div>Peter<br><div><div><div><div><div><br><br></div></d= iv></div></div></div></div><div class=3D"gmail_extra"><br><div class=3D"gma= il_quote">On 17 February 2016 at 09:38, Matt Rhys-Roberts (<a href=3D"mailt= o:matt DOT rhys-roberts AT envinsci DOT co DOT uk">matt DOT rhys-roberts AT envinsci DOT co DOT uk</a>) [= via <a href=3D"mailto:geda-user AT delorie DOT com">geda-user AT delorie DOT com</a>] <sp= an dir=3D"ltr"><<a href=3D"mailto:geda-user AT delorie DOT com" target=3D"_blan= k">geda-user AT delorie DOT com</a>></span> wrote:<br><blockquote class=3D"gmai= l_quote" style=3D"margin:0 0 0 .8ex;border-left:1px #ccc solid;padding-left= :1ex">I'm trying to pre-set the default DRC settings on my old version = of pcb (20110918 Compiled on Jul=C2=A0 2 2013 at 11:26:16).<br> <br> There is nothing I can do to make pcb remember any kind of DRC settings fro= m project to project. What you tell me should work, doesn't.<br> <br> Please can anyone tell me what settings/config file to create or edit, so t= hat every time I open a new instance of pcb, the DRC settings are just ther= e? Or doesn't it work that way?<br> <br> Kind regards,<br> Matt.<br> </blockquote></div><br></div> --089e0118427ad0717f052bf66afc--
webmaster | delorie software privacy |