delorie.com/archives/browse.cgi   search  
Mail Archives: geda-user/2016/01/10/03:34:00

X-Authentication-Warning: delorie.com: mail set sender to geda-user-bounces using -f
X-Recipient: geda-user AT delorie DOT com
X-Original-DKIM-Signature: v=1; a=rsa-sha256; c=relaxed/relaxed;
d=gmail.com; s=20120113;
h=date:from:to:subject:message-id:in-reply-to:references:mime-version
:content-type:content-transfer-encoding;
bh=z2UCOdnMa8gS9WvCA8emIcnp+79jdgEF2VfqYp1HlVQ=;
b=W7OhVXBFZRbnWHBgw5Nyq3zfEneEo5U3Js+w19im3YCEGAL+NXwdboca54xg6zQ6Ar
NlAPjvaTKaYSxpFW+PkFYijC7dYhnATvYJf4gKIfcqYmjXjj7HHxyWl+5ewtMDsHL+Om
Vc/Y2BDzMannZh6TQ17oJvCLW39edgXeUbX6Bt6GbcTIFWczaosN7pATem8uytxz9snH
UGLJau9Vi3u2yUTl0R+zAdlq+CbK1cDCp5jA9jz8C3CpFxAUH6weHcIPzVZcJ6yj3idF
70zkG+ZibNBumZEOVPtnSIyoSdRswByKuuh/3OZe4u3yHK6SxrbIPNs1Fd8Mu1uUwGEC
crew==
X-Received: by 10.25.26.210 with SMTP id a201mr20844830lfa.57.1452414823717;
Sun, 10 Jan 2016 00:33:43 -0800 (PST)
Date: Sun, 10 Jan 2016 09:33:42 +0100
From: "Nicklas Karlsson (nicklas DOT karlsson17 AT gmail DOT com) [via geda-user AT delorie DOT com]" <geda-user AT delorie DOT com>
To: geda-user AT delorie DOT com
Subject: Re: [geda-user] (draw on insulating layers)
Message-Id: <20160110093342.4921169f9b26a07abe28139c@gmail.com>
In-Reply-To: <s6nio3249l9.fsf@blaulicht.dmz.brux>
References: <1512221837 DOT AA25291 AT ivan DOT Harhan DOT ORG>
<CACwWb3BXbnQXs+DwVVzmC8DrhwOYxPgVyUhZTPL9bM9cJbHimw AT mail DOT gmail DOT com>
<20160106164022 DOT D0D4E809D79B AT turkos DOT aspodata DOT se>
<20160106180912 DOT 42ddf4079d91384f206b7c35 AT gmail DOT com>
<20160106191433 DOT 5dc5cb59 AT jive DOT levalinux DOT org>
<20160106202817 DOT 56197b2c539d426a1b724c9e AT gmail DOT com>
<568E09ED DOT 1080508 AT m0n5t3r DOT info>
<CACwWb3AhSh-+NNu--bVMGZBfjaoA+hHg7gbXnoyNv3oMq=e17g AT mail DOT gmail DOT com>
<568E6354 DOT 80302 AT m0n5t3r DOT info>
<20160108002640 DOT 03233b24 AT jive DOT levalinux DOT org>
<20160108175259 DOT 127a3f073616758434f7edff AT gmail DOT com>
<20160109020345 DOT 1e07cb84 AT jive>
<BD84C322-333F-4A59-8CBC-54927A6B2855 AT noqsi DOT com>
<882E12BE-93AD-4A43-B87A-65F05269D6B4 AT noqsi DOT com>
<20160109193526 DOT 9f998ebeec0141b637ff5751 AT gmail DOT com>
<8A0C79D4-975F-4CD8-8227-2CB050304412 AT noqsi DOT com>
<201601092000 DOT u09K0HT9009084 AT envy DOT delorie DOT com>
<FB13174D-DBA3-467C-8A08-744422953341 AT noqsi DOT com>
<201601092139 DOT u09LdAGQ013146 AT envy DOT delorie DOT com>
<s6nio3249l9 DOT fsf AT blaulicht DOT dmz DOT brux>
X-Mailer: Sylpheed 3.5.0beta1 (GTK+ 2.24.25; x86_64-pc-linux-gnu)
Mime-Version: 1.0
X-MIME-Autoconverted: from quoted-printable to 8bit by delorie.com id u0A8Xo4F032287
Reply-To: geda-user AT delorie DOT com
Errors-To: nobody AT delorie DOT com
X-Mailing-List: geda-user AT delorie DOT com
X-Unsubscribes-To: listserv AT delorie DOT com

On Sun, 10 Jan 2016 00:27:46 +0100
geda AT psjt DOT org (Stephan Böttcher) wrote:

> DJ Delorie <dj AT delorie DOT com> writes:
> 
> >> Inventing your own private meanings for common words is not a good
> >> path to comprehension.
> >
> > I didn't invent them.
> >
> > And they're pretty common in industry.  (example: photoshop layers
> > aren't always "material" and Eagle has more layers than just the
> > physical ones)
> 
> The Gerber spec that you can find following links from the gerbv page
> replaced the word "layer" with "levels" when talking about stacking
> polarity.  Basically, whenever you switch from positive to negative
> polarity or back, a new "level" is entered implicitly.
> 
> Stephan

I would say even if gerber have proble handling negative polarity workaround is done today for copper layers and work so it would make sense with cut out in pcb/gpcb. I think a cut outs width height would make sense for footprint court yard it would "say" space is needed and if placed on internal layer it would cut thru material above it.



I also discovered Acamco realeased a new gerber specification first of January this year.


Nicklas Karlsson