On Mon, 27 Jul 2015, Gabriel Paubert (paubert AT iram DOT es) [via geda-user AT delorie DOT com] wrote: Thanks for the details! I have one question about stubs. > In both cases: > - these are point to point signals and stubs are essentially prohibited, http://nxp.com/documents/application_note/AN10935.pdf fig 4 on page 9 shows how two DDR rams connected to a single MCU. There are regular T junctions there. I guess with proper trace lengths/impedances/termination this should be possible. I've seen such topology (in application notes) before, that made me think the best would be to calculate lengths independently on all the three arms of the T. Does this idea make sense? Regards, Igor2