On Jun 29, 2015, at 2:33 PM, DJ Delorie <dj AT delorie DOT com> wrote:
>
>> John, I have frequently marked off in the comment field how long/wide
>> traces can/should be. It would be nice if there was some meaningful
>> way to pass that to PCB. That would involve gschem changes in minor
>> ways. I am not asking anyone to implement this. Just defending a
>> position.
>
> File->Import imports all attributes as element attributes. I don't
> know of anything that *does* anything with it though, aside from some
> BOM scripts.
>
Yeah, but the problem is that it can’t import attributes of net segments, since they aren’t in one of the gnetlist views. Gnetlist can’t even see the segments, only the glommed-together nets. And then, nets aren’t “elements”.
One useful thing you could do if gnetlist could peruse the net segments and their attributes is to detect renamed nets in hierarchy, and make appropriate aliases for SPICE. It’s a pain to have to manually trace a net up two levels to figure out its name in order to plot its voltage. DRC could also detect schematic-level shorts with this capability.
John Doty Noqsi Aerospace, Ltd.
http://www.noqsi.com/