delorie.com/archives/browse.cgi | search |
X-Authentication-Warning: | delorie.com: mail set sender to geda-user-bounces using -f |
X-Recipient: | geda-user AT delorie DOT com |
Date: | Fri, 06 Mar 2015 05:58:29 -0500 |
From: | gene glick <geneglick AT optonline DOT net> |
Subject: | Re: [geda-user] [OT] Temperature sensor and control recommendation |
In-reply-to: | <201503051621.t25GL09H018380@envy.delorie.com> |
To: | geda-user AT delorie DOT com |
Message-id: | <54F98855.4060903@optonline.net> |
MIME-version: | 1.0 |
References: | |
<CAF3uCZ=G0FztqBtpfvssYCz9WrUORX8+J45xmH9+KutaX6c+gw AT mail DOT gmail DOT com> | |
<201503051621 DOT t25GL09H018380 AT envy DOT delorie DOT com> | |
User-Agent: | Mozilla/5.0 (X11; Linux x86_64; rv:36.0) Gecko/20100101 |
Thunderbird/36.0 | |
X-MIME-Autoconverted: | from QUOTED-PRINTABLE to 8bit by delorie.com id t26AwNXB004329 |
Reply-To: | geda-user AT delorie DOT com |
Errors-To: | nobody AT delorie DOT com |
X-Mailing-List: | geda-user AT delorie DOT com |
X-Unsubscribes-To: | listserv AT delorie DOT com |
On 03/05/2015 11:21 AM, DJ Delorie wrote: > >> I'm facing the need to control the temperature of a small sample in a >> chamber between room temperature and about 450°C with a precision of >> 0.3°C or better. > > I use a thermocouple to monitor my woodstove, but I don't care so much > about precision. I use a DS2760 thermocouple kit from Parallax for > it, and a high-temp thermocouple probe from Omega.com. > > For monitoring my geothermal system, I used RTDs and an MCU's ADC to > measure them. I got extra precision by doing each measurement 64 > times and averaging, and the tech who calibrated my geothermal system > says they're spot-on. > > I use the same averaging trick on my thermostats to get 0.1F readings > on a 1C-rated sensor. If your sensor isn't noisy enough to use this > trick, you can always add noise - you're basically building a 1-bit > ADC. > > we use this trick at work as well - converts a 12-bit ADC to 16-bit precision. I think the relationship requires you need 2^n samples for each bit of additional resolution. This is off the top of my head, but is probably close. So if I remember correctly, we had to sample an extra 16X to get the additional 4-bit precision. It works really well. But yes, it relies on noise to work and assumes the measurement is relatively stable over the sampling period. I believe the technical term for this trick is decimation. gene