Gabriel Paubert wrote: > The temperature range was specified as -200C to 260C, they recently > changed the lower end of the temperature range to -70C. .. > Reducing the range of a temperature probe by 130C without even > touching the part number is unacceptable in my eyes I don't expect that they made any change to the probes. They just fixed the documentation. My guess is that your old probes have exactly the same performance as new ones. //Peter