Subject: Re: [geda-user] Converting schematic from OrCAD to gschem
From: Peter Clifton <pcjc2 AT cam DOT ac DOT uk>
To: geda-user AT delorie DOT com
Date: Tue, 06 Jan 2015 08:13:44 +0000
In-Reply-To: <CAGMfzYSm=CYbfm-ueJcE0KPDWyQwTkvc216AT4Rk_G=h4rasSw@mail.gmail.com>
References:
<CAGMfzYQvEGxbi69-UFY5sWkRmKK5wE50puODBC2RbSiZ8mi1wA AT mail DOT gmail DOT com>
<20141230082942 DOT GA4024 AT localhost DOT localdomain>
<CAOFvGD7UtXTWGCJG_ezPLHgs_9p+X2OqHpFtU-vuW5SyOnDr2Q AT mail DOT gmail DOT com>
<CAGMfzYSm=CYbfm-ueJcE0KPDWyQwTkvc216AT4Rk_G=h4rasSw AT mail DOT gmail DOT com>
X-Mailer: Evolution 3.12.7-0ubuntu1
Mime-Version: 1.0
Reply-To: geda-user AT delorie DOT com
Errors-To: nobody AT delorie DOT com
X-Mailing-List: geda-user AT delorie DOT com
X-Unsubscribes-To: listserv AT delorie DOT com

On Tue, 2014-12-30 at 17:27 +0000, Katya M. wrote:

[snip]

> If it takes no more than 5 minutes, might it perhaps be possible for
> you to open that DSN file I'm dealing with (link below) in your OrCAD
> setup and export the BOM information? When I run strings on the binary
> file, I see what looks like a lot of useful information: names of PCB
> footprints, orderable part numbers etc - information that does not
> appear in any of the PDF schematics I found for this >10 y old
> reference board. (I'm guessing this info is OrCAD's equivalent of
> gschem's invisible attributes - they are there, but not shown on PDF
> prints.)
> 
> Here is the file again:
> 
> ftp://ftp.ifctf.org/pub/GSM/Calypso/Leonardo_rev05.dsn
> 
> TIA,
> Katya


Perhaps try the PADS2000 netlist export. IIRC, the netlist format is
ASCII, and easily parsed / translated to PCB if required.

(I've built gEDA/PCB layouts from Orcad capture schematics that way
before.. it was simple enough to hand-process the netlist with sed
etc.., rather than write a netlist translator).


Peter

-- 
Peter Clifton <peter DOT clifton AT clifton-electronics DOT co DOT uk>

Clifton Electronics