Mail Archives: geda-user/2014/05/26/12:20:44.1
On 05/26/2014 06:03 AM, Kai-Martin Knaak wrote:
> Dave McGuire wrote:
>
>> Found it...Select all traces by turning off everything else, select
>> all visible, then ":ChangeSize(SelectedLines, 7)". (for 7mils)
>
> IIRC, the size parameter is 1/100 of a mil by default.
>
> I recommend to use the unit parameter to reduce this kind of
> ambiguity. To achieve 7 mil width:
> ChangeSize(SelectedLines, 7, mil)
Yes I learned that the hard way after my post. ;) Thanks for the
clarification.
> BTW, in section "actions" the manual still refers to 1/100 mil as the
> internal unit of pcb
> http://pcb.geda-project.org/pcb-cvs/pcb.html#Actions
>
> It only mentions "mm" and "mil". In fact, pcb deals gracefully with
> the usual multiples, too. E.g. "m", "nm", "um", ...
> No "ly", though ;-)
;)
-Dave
--
Dave McGuire, AK4HZ
New Kensington, PA
- Raw text -