delorie.com/archives/browse.cgi | search |
X-Authentication-Warning: | delorie.com: mail set sender to geda-user-bounces using -f |
X-Recipient: | geda-user AT delorie DOT com |
Message-ID: | <530FA6A2.9030209@estechnical.co.uk> |
Date: | Thu, 27 Feb 2014 20:57:06 +0000 |
From: | Ed Simmons <ed AT estechnical DOT co DOT uk> |
User-Agent: | Mozilla/5.0 (X11; Linux x86_64; rv:24.0) Gecko/20100101 Thunderbird/24.3.0 |
MIME-Version: | 1.0 |
To: | geda-user AT delorie DOT com |
Subject: | Re: [geda-user] Via under a pad? |
References: | <CALSZ9gohqcqTT7y8x8x2wZdrcv8s2M-DhaN8vB5Zf6uvpRrCYA AT mail DOT gmail DOT com> |
In-Reply-To: | <CALSZ9gohqcqTT7y8x8x2wZdrcv8s2M-DhaN8vB5Zf6uvpRrCYA@mail.gmail.com> |
X-Authenticated-As: | ed AT estechnical DOT co DOT uk |
X-Extend-Src: | mailout |
Reply-To: | geda-user AT delorie DOT com |
Hi Rob, On 27/02/14 20:01, Rob Butts wrote: > Is it bad practice to put vias under pads? These pads are twice as > big as the vias. > > Just curious. Can you afford the via being much smaller? We put vias 'in pad' but make sure they're really small so they don't suck up away the solder. Typically, I tend to try and place vias next to the pad unless absolutely necessary. On the other hand, for heat sinking with the PCB, we use an array of the smallest vias our fab house will drill (0.2mm hole) under the large heat sink pad of SMT mosfets or transistors, with a large copper fill on as many layers as possible to dissipate the heat. It depends on what you're doing as to which approach is right. ;-) Hope that helps! Ed
webmaster | delorie software privacy |
Copyright © 2019 by DJ Delorie | Updated Jul 2019 |