delorie.com/archives/browse.cgi | search |
X-Authentication-Warning: | delorie.com: mail set sender to geda-user-bounces using -f |
X-Recipient: | geda-user AT delorie DOT com |
Message-ID: | <513A321A.5080905@xs4all.nl> |
Date: | Fri, 08 Mar 2013 19:46:50 +0100 |
From: | Bert Timmerman <bert DOT timmerman AT xs4all DOT nl> |
User-Agent: | Mozilla/5.0 (X11; U; Linux i686; en-US; rv:1.9.1.19) Gecko/20110429 Fedora/2.0.14-1.fc13 SeaMonkey/2.0.14 |
MIME-Version: | 1.0 |
To: | geda-user AT delorie DOT com |
Subject: | Re: [geda-user] IPC-D-356 netlist format |
References: | <5139FF95 DOT 8010202 AT iastate DOT edu> <20130308160733 DOT GA15248 AT recycle DOT lbl DOT gov> |
In-Reply-To: | <20130308160733.GA15248@recycle.lbl.gov> |
X-Virus-Scanned: | by XS4ALL Virus Scanner |
Reply-To: | geda-user AT delorie DOT com |
Larry Doolittle wrote: > Roy - > > On Fri, Mar 08, 2013 at 09:11:17AM -0600, Roy McKay wrote: > >> Does anyone have a script that can translate gschem netlist to >> IPC-D-356 format? The board house demands the IPC netlist for >> electrical testing of my board. And yes they can generate it from >> the Gerbers, but a netlist from the source serves as a check. >> > The IPC-D-356 file should be generated from PCB, not gschem. > The file needs to have coordinates of the component pads, not > just abstract connectivity. > > - Larry > > The ongoing effort to implement IPC-D-356 exporting functionality is described here: https://bugs.launchpad.net/pcb/+bug/996319 Unfortunately I do not have many spare cycles in the coming weeks to debug, tweak and commit the code for this one. Kind regards, Bert Timmerman.
webmaster | delorie software privacy |
Copyright © 2019 by DJ Delorie | Updated Jul 2019 |