Message-ID: <4d3c7def-4fa6-4095-82ba-35fccf82520c@email.android.com>
X-Provags-ID: V02:K0:nzqEiJrZbt9bdfII6nbjTPwyTkieWVamMC+Ywhetl1x
rvDyTm8wn+yAwufJVx1k9xnq3CXpNAJJcLllIzrEc53Na/+idb
GJ123+6ctg4ibE/QXKjv0niT3FqXGpIGNjunQZyGMtS+4510ed
x7BTcSWb1CYBauOlxWyVICeq/82iprMWbk0ngXynaZ6woLyVtb
8X6NymjE3QnHrUgfC/vcxqXviKNfkCN8Kzk1KGlUWzKEWjpKkL
2pbLc6TPSU2pQWslycfWtiWTjwHyR74mxqI+3/1Ty0aUaZiUhT
qmYvouh/R4J80VoXWpUVKW3Kcj5EAXM1S0JBFevd6AtIb/3f8x
YwcWDHzuI18d+78fJaXHEvWB9azks+r7C7mbjkOs2nkDtV3e84
olh6QZOyCTnRA==
Reply-To: geda-user AT delorie DOT com
Errors-To: nobody AT delorie DOT com
X-Mailing-List: geda-user AT delorie DOT com
X-Unsubscribes-To: listserv AT delorie DOT com

------GIHZVFMQUPEI4M93217IZ8B1YD56I8
Content-Transfer-Encoding: quoted-printable
Content-Type: text/plain;
 charset=UTF-8

Jan Kasprzak <kas AT fi DOT muni DOT cz> wrote:

>	The other problem is that the whole=
 process (gschem -> gsch2pcb ->
>pcb)
>_silently_ discards the nets with no=
n-numeric pinnumbers. So you start
>with
>a schematics, run gsch2pcb and pc=
b, and the resulting layout has
>missing
>connections, without _any_ notifi=
cation that something is wrong.
>
Type [o] in pcb and the log window will w=
arn about connections in the netlist for which it can't find pins in the la=
yout.
If you do import schematic from the pcb GUI, there may be a pop-up di=
alog.
---<)kaimartin (>---
-- 
Kai-Martin Knaak
email: kmk AT familieknaak DOT de
=
=C3=B6ffentlicher PGP-Schl=C3=BCssel: 0x6C0B9F53

-- 
Kai-Martin Knaak
emai=
l: kmk AT familieknaak DOT de
=C3=B6ffentlicher PGP-Schl=C3=BCssel: 0x6C0B9F53

------GIHZVFMQUPEI4M93217IZ8B1YD56I8
Content-Type: text/html;
 charset=utf-8
Content-Transfer-Encoding: quoted-printable

<html><head/><body>Jan Kasprzak &lt;kas AT fi DOT muni DOT cz&gt; wrote:<br>
<br>
&gt;=
	The other problem is that the whole process (gschem -&gt; gsch2pcb -&gt;<b=
r>
&gt;pcb)<br>
&gt;_silently_ discards the nets with non-numeric pinnumber=
s. So you start<br>
&gt;with<br>
&gt;a schematics, run gsch2pcb and pcb, an=
d the resulting layout has<br>
&gt;missing<br>
&gt;connections, without _an=
y_ notification that something is wrong.<br>
&gt;<br>
Type [o] in pcb and t=
he log window will warn about connections in the netlist for which it can&#=
39;t find pins in the layout.<br>
If you do import schematic from the pcb G=
UI, there may be a pop-up dialog.<br>
---&lt;)kaimartin (&gt;---<br>
-- <br=
>
Kai-Martin Knaak<br>
email: kmk AT familieknaak DOT de<br>
=C3=B6ffentlicher PGP=
-Schl=C3=BCssel: 0x6C0B9F53<br>
<br>
-- <br>
Kai-Martin Knaak<br>
email: km=
k AT familieknaak DOT de<br>
=C3=B6ffentlicher PGP-Schl=C3=BCssel: 0x6C0B9F53<br>
=
</body></html>
------GIHZVFMQUPEI4M93217IZ8B1YD56I8--

- Raw text -


  webmaster     delorie software   privacy  
  Copyright © 2019   by DJ Delorie     Updated Jul 2019