delorie.com/archives/browse.cgi | search |
X-Authentication-Warning: | delorie.com: mail set sender to geda-user-bounces using -f |
X-Recipient: | geda-user AT delorie DOT com |
X-Recipient: | geda-user AT delorie DOT com |
User-Agent: | K-9 Mail for Android |
In-Reply-To: | <20130131100136.GP32216@fi.muni.cz> |
References: | <20130130090351 DOT GE32216 AT fi DOT muni DOT cz> <1359555319 DOT 2295 DOT 9 DOT camel AT AMD64X2> <alpine DOT DEB DOT 2 DOT 00 DOT 1301310418000 DOT 7105 AT igor2priv> <20130131100136 DOT GP32216 AT fi DOT muni DOT cz> |
MIME-Version: | 1.0 |
Subject: | Re: [geda-user] [patch] Pinnumbers in mosfet-with-diode-1.sym |
From: | Kai-Martin Knaak <kmk AT familieknaak DOT de> |
Date: | Thu, 31 Jan 2013 11:41:35 +0100 |
To: | geda-user AT delorie DOT com, geda-user AT delorie DOT com |
Message-ID: | <4d3c7def-4fa6-4095-82ba-35fccf82520c@email.android.com> |
X-Provags-ID: | V02:K0:nzqEiJrZbt9bdfII6nbjTPwyTkieWVamMC+Ywhetl1x |
rvDyTm8wn+yAwufJVx1k9xnq3CXpNAJJcLllIzrEc53Na/+idb | |
GJ123+6ctg4ibE/QXKjv0niT3FqXGpIGNjunQZyGMtS+4510ed | |
x7BTcSWb1CYBauOlxWyVICeq/82iprMWbk0ngXynaZ6woLyVtb | |
8X6NymjE3QnHrUgfC/vcxqXviKNfkCN8Kzk1KGlUWzKEWjpKkL | |
2pbLc6TPSU2pQWslycfWtiWTjwHyR74mxqI+3/1Ty0aUaZiUhT | |
qmYvouh/R4J80VoXWpUVKW3Kcj5EAXM1S0JBFevd6AtIb/3f8x | |
YwcWDHzuI18d+78fJaXHEvWB9azks+r7C7mbjkOs2nkDtV3e84 | |
olh6QZOyCTnRA== | |
Reply-To: | geda-user AT delorie DOT com |
Errors-To: | nobody AT delorie DOT com |
X-Mailing-List: | geda-user AT delorie DOT com |
X-Unsubscribes-To: | listserv AT delorie DOT com |
------GIHZVFMQUPEI4M93217IZ8B1YD56I8 Content-Transfer-Encoding: quoted-printable Content-Type: text/plain; charset=UTF-8 Jan Kasprzak <kas AT fi DOT muni DOT cz> wrote: > The other problem is that the whole= process (gschem -> gsch2pcb -> >pcb) >_silently_ discards the nets with no= n-numeric pinnumbers. So you start >with >a schematics, run gsch2pcb and pc= b, and the resulting layout has >missing >connections, without _any_ notifi= cation that something is wrong. > Type [o] in pcb and the log window will w= arn about connections in the netlist for which it can't find pins in the la= yout. If you do import schematic from the pcb GUI, there may be a pop-up di= alog. ---<)kaimartin (>--- -- Kai-Martin Knaak email: kmk AT familieknaak DOT de = =C3=B6ffentlicher PGP-Schl=C3=BCssel: 0x6C0B9F53 -- Kai-Martin Knaak emai= l: kmk AT familieknaak DOT de =C3=B6ffentlicher PGP-Schl=C3=BCssel: 0x6C0B9F53 ------GIHZVFMQUPEI4M93217IZ8B1YD56I8 Content-Type: text/html; charset=utf-8 Content-Transfer-Encoding: quoted-printable <html><head/><body>Jan Kasprzak <kas AT fi DOT muni DOT cz> wrote:<br> <br> >= The other problem is that the whole process (gschem -> gsch2pcb -><b= r> >pcb)<br> >_silently_ discards the nets with non-numeric pinnumber= s. So you start<br> >with<br> >a schematics, run gsch2pcb and pcb, an= d the resulting layout has<br> >missing<br> >connections, without _an= y_ notification that something is wrong.<br> ><br> Type [o] in pcb and t= he log window will warn about connections in the netlist for which it can&#= 39;t find pins in the layout.<br> If you do import schematic from the pcb G= UI, there may be a pop-up dialog.<br> ---<)kaimartin (>---<br> -- <br= > Kai-Martin Knaak<br> email: kmk AT familieknaak DOT de<br> =C3=B6ffentlicher PGP= -Schl=C3=BCssel: 0x6C0B9F53<br> <br> -- <br> Kai-Martin Knaak<br> email: km= k AT familieknaak DOT de<br> =C3=B6ffentlicher PGP-Schl=C3=BCssel: 0x6C0B9F53<br> = </body></html> ------GIHZVFMQUPEI4M93217IZ8B1YD56I8--
webmaster | delorie software privacy |
Copyright © 2019 by DJ Delorie | Updated Jul 2019 |