Typical numbers are 8-10 mil copper clearance and 3 mil mask
clearance.

"Clearance" is the distance between the two.  A 40 mil diameter copper
pad with 3 mil mask clearance means the mask hole will be 46 mil
diameter.

http://www.delorie.com/pcb/docs/gs/gs.html#Terminology