On 07/20/2012 08:00 PM, Nathan Stewart wrote: > Do any of the budget fab houses do internal routing? Sure. Every power supply board with UL or ETL listing needs slots for isolation between volts and ground. It provides surface path distance to prevent conduction due to dust and salts in the air collecting on pcb's. It's a probabalistic treatment for long years of use not causing a fire hazard.