delorie.com/archives/browse.cgi   search  
Mail Archives: geda-user/2012/07/19/19:52:52

X-Authentication-Warning: delorie.com: mail set sender to geda-user-bounces using -f
X-Recipient: geda-user AT delorie DOT com
X-Authority-Analysis: v=2.0 cv=AtpsLZBP c=1 sm=0 a=6jktZp3dcHAl1vye2O6wCg==:17 a=jl9P3j1e7_0A:10 a=2xJ3G-9csIsA:10 a=8hO_kANTrYkA:10 a=6WB07kdHjWAA:10 a=8nJEP1OIZ-IA:10 a=wR-FlJDvAAAA:8 a=dztWTzYJtTbDwv-IP8gA:9 a=wPNLvfGTeEIA:10 a=6jktZp3dcHAl1vye2O6wCg==:117
X-Cloudmark-Score: 0
X-Originating-IP: 70.113.67.117
Message-ID: <50089DC4.7020006@ecosensory.com>
Date: Thu, 19 Jul 2012 18:52:36 -0500
From: John Griessen <john AT ecosensory DOT com>
User-Agent: Mozilla/5.0 (X11; Linux i686; rv:10.0.4) Gecko/20120510 Icedove/10.0.4
MIME-Version: 1.0
To: geda-user AT delorie DOT com
Subject: Re: [geda-user] pcb footprint update hack
References: <20120719182728 DOT GA12447 AT slana DOT eecs DOT oregonstate DOT edu> <201207191846 DOT q6JIkbTb030133 AT envy DOT delorie DOT com> <20120719160003 DOT 3a3fb538 AT svelte> <201207192322 DOT q6JNMhYj012483 AT envy DOT delorie DOT com>
In-Reply-To: <201207192322.q6JNMhYj012483@envy.delorie.com>
Reply-To: geda-user AT delorie DOT com

On 07/19/2012 06:22 PM, DJ Delorie wrote:
>> 1. Rename the old footprint file to a different name:
>
> It's a lot safer to rename the footprint in the *.pcb, then you don't
> have to change a possibly-shared library.  This way also means you
> import only once.

So, would this be the procedure?

Suppose you have the following set of files for your project, for
simplicity's sake:

   Board.pcb
   Schematic.sch
   XYZ123.fp

Suppose further that you have 50 instances of XYZ123 on your
schematic.  You really don't want to do this manually.

1. search and replace with sed or ? on the file Board.pcb to replace XYZ123.fp with XYZ123_new.fp

2. Replace all instances of this in your schematic with the temporary
    name:
    sed -i -e 's/footprint=XYZ123/footprint=XYZ123_new/'

2a.  create file XYZ123_new.fp

3. Open the layout in pcb and update the layout from schematic.
    pcb Board.pcb
    Execute File | Import Schematics.

4. You might have to fix some components, they sometimes are
    rotated incorrectly after being updated.  Use the rotate tool
    and click on the component reference point (diamond) until
    things are lined up.

5. Save the layout.

But now you have a name of XYZ123_new.fp.  How do you get to modified XYZ123.fp
in fewer steps that Colin suggested?  Or are you suggesting always use anew name?

John