Andrew Poelstra ha scritto lo scorso 28/05/2012 22:16: > > Hey all, > > Does anyone have experience with the TPS40210 switching power > supply? It is a fairly new chip from TI. > > My question is: can I connect the thermal relief pad to GND? > The datasheet says nothing about internal connections to the > thermal pad. > Hi, not sure about 40210, but I've already used the TPS5450 (SO8+PowerPad) and the TPS62172 (WSON8+PowerPad); in both cases I connected the PwPad to ground (and to an "onsolder,nopaste" pad connected by vias to the component-side PwPad for thermal dissipation and - mainly - for paste draining).