On Mon, May 28, 2012 at 01:16:59PM -0700, Andrew Poelstra wrote: > > Hey all, > > Does anyone have experience with the TPS40210 switching power > supply? It is a fairly new chip from TI. > > My question is: can I connect the thermal relief pad to GND? > The datasheet says nothing about internal connections to the > thermal pad. Indeed. But look at example 1, they have a "mysterious" pin number 11 named PwPd (which can only be the thermal pad) which is connected to ground. So I'd say that you can connect it ground, whether it is electrically connected to ground inside the chip or not is irrelevant (easy to check with a low voltage ohmmeter). Gabriel