| delorie.com/archives/browse.cgi | search |
| X-Authentication-Warning: | delorie.com: mail set sender to geda-user-bounces using -f |
| Date: | Wed, 23 May 2012 14:13:25 -0400 |
| Message-Id: | <201205231813.q4NIDP9P025903@envy.delorie.com> |
| From: | DJ Delorie <dj AT delorie DOT com> |
| To: | geda-user AT delorie DOT com |
| In-reply-to: | |
| <CALSZ9gqGJ3i7vG-E+Y1jP8inHr=HeL10jZGXTOqeSVScZT4_iQ AT mail DOT gmail DOT com> | |
| (message from Rob Butts on Wed, 23 May 2012 14:08:06 -0400) | |
| Subject: | Re: [geda-user] PCB touch electrode pad covered in mask |
| References: | <CALSZ9gqGJ3i7vG-E+Y1jP8inHr=HeL10jZGXTOqeSVScZT4_iQ AT mail DOT gmail DOT com> |
| Reply-To: | geda-user AT delorie DOT com |
Mask value should be independent of copper size (else how would you do mask-defined openings for bgas?) Just use shift-k (while the mask layer is visible) until the mask opening closes completely.