delorie.com/archives/browse.cgi   search  
Mail Archives: geda-user/2012/03/20/10:59:17

X-Authentication-Warning: delorie.com: mail set sender to geda-user-bounces using -f
X-Recipient: geda-user AT delorie DOT com
X-Authority-Analysis: v=2.0 cv=d9t3OGfE c=1 sm=0 a=6jktZp3dcHAl1vye2O6wCg==:17 a=jl9P3j1e7_0A:10 a=M_ffKnrP7SkA:10 a=KgyqOKasUc8A:10 a=6WB07kdHjWAA:10 a=8nJEP1OIZ-IA:10 a=UGKU2GPCmjgKRli3EYoA:9 a=wPNLvfGTeEIA:10 a=6jktZp3dcHAl1vye2O6wCg==:117
X-Cloudmark-Score: 0
X-Originating-IP: 70.113.67.117
Message-ID: <4F689B37.8080607@ecosensory.com>
Date: Tue, 20 Mar 2012 09:59:03 -0500
From: John Griessen <john AT ecosensory DOT com>
User-Agent: Mozilla/5.0 (X11; Linux i686; rv:8.0) Gecko/20120216 Icedove/8.0
MIME-Version: 1.0
To: geda-user AT delorie DOT com
Subject: Re: [geda-user] repetitive circuits
References: <CACPio-6438uNhTCPB8bi_ROtAaudBWO2nWUwms6U-+LS=jh3Cw AT mail DOT gmail DOT com> <4F67BB67 DOT 1030004 AT ecosensory DOT com> <CACPio-7f0aAH5iF9KHkpVB2EpCFj+NefQ8XXKHN7a1cgAqRaOA AT mail DOT gmail DOT com>
In-Reply-To: <CACPio-7f0aAH5iF9KHkpVB2EpCFj+NefQ8XXKHN7a1cgAqRaOA@mail.gmail.com>
Reply-To: geda-user AT delorie DOT com

On 03/19/2012 08:24 PM, Nathan Stewart wrote:
>   What about refdes
> incrementing and assignment? Right now I've got my filter laid out so
> that there are 6 channels, each using 2 channels of a quad opamp.

For that, you would need to separate out the repeated part and assign it
different refdes names as you place each schematic block.  The names inside each schematic
need to be prefixed with refdes also, as gschem has no automatic method of handling hierarchy,
it is not native to the netlist at this time.

- Raw text -


  webmaster     delorie software   privacy  
  Copyright © 2019   by DJ Delorie     Updated Jul 2019