On Tue, 2012-03-13 at 09:38 -0400, Nathan Stewart wrote:

> BTW - is there a better way to deal with rats going to ground? It seems to
> want to connect them to "nearby" components when they could be a lot less
> confusing if they picked another point at ground.
> 
> Thanks

You can hide the GND rats -- Select Windows -> Nelist from menu, double
click on GND or AGND or whatever you want to hide. A * should appear at
the left. Not click on the main window with the pcb layout and press "o"
key to optimize rats. GND rats should disappear.