Gang,
I have a netlist with two different t-lines. One uses
the TXL model, the other the LTRA model. Both are lossy.
I am modeling RG-58 coax. I sweep frequencies from 1Mhz
to 1Ghz.
When using the LTRA model, everything works. I have the
0.3 meter length of cable shorted at the far end and see
nice standing waves.
When using the TXL model, the input to the cable looks like
50ohms, but there are no standing waves.
Any ideas? Netlist follows.
Thanks,
Roger Traylor
--------------------------------------------------------
Simple T line with standing waves
Vin vin 0 dc 0.0 ac 1.0 sin(0 1.0)
Rsrc vin t1_in 50
try the TXL model
*y1 t1_in 0 t1_out 0 ymodel LEN=0.3
*.MODEL ymodel txl R=0.035 L=252n G=0 C=102.4p length=0.3
*try the LTRA model
O1 t1_in 0 t1_out 0 LOSSYMOD
.MODEL LOSSYMOD LTRA R=0.035 L=252n G=0 C=102.4p len=0.3
rload t1_out 0 0.1
.control
ac lin 100000 1Meg 1000Meg
plot vm(t1_in) vm(t1_out) vm(vin)
.endc
.end