Am Tue, 23 Feb 2016 08:03:14 -0700
schrieb John Doty <jpd AT noqsi DOT com>:
> On Feb 23, 2016, at 6:09 AM, Smilie (smilie AT posteo DOT de) [via
> geda-help AT delorie DOT com] <geda-help AT delorie DOT com> wrote:
>
> > Ah, i see.
> >
> >
> > i have connected a line from GND.sym direct to one of the GND-Pins
> > and the other GND-Pin works also.
>
> What are you trying to do here?
I want do write a script for automatic generation a spreadsheet with
all pin-names for any connector. I try to generate it from the
netlist-stuff.
But it does not work if i have only one potential.
The test with netname also does not work.
>
> What these symbols do is to give a net a name. That’s all. Naming the
> net connected to a pin GND connects it to all other nets named GND.
> If you have more than one such symbol, and the names don’t match,
> gnetlist will choose the first one it sees.
>
> Is your net connected to anything?
>
> >
> > It is a bug?
> > I broke my head....
> >
> > Thanks for helping me.
> >
> >
> >
> >
> > Am Tue, 23 Feb 2016 10:20:16 +0000
> > schrieb "Peter Clifton (petercjclifton AT googlemail DOT com) [via
> > geda-help AT delorie DOT com]" <geda-help AT delorie DOT com>:
> >
> >> Sorry I'm not currently able to check this out, but I recall that
> >> gnetlist has (in the past, and possibly currently), not worked
> >> properly in the case where only IO symbols with net=....:1
> >> attributes (but no actual components).
> >>
> >> My recollection is not that clear, but try adding a dummy component
> >> (perhaps a resistor), with one pin connected on your schematic
> >> where you join PGND and your IO sym. Don't need to give it a
> >> footprint (but you will probably get complaints from pcb about the
> >> missing component).
> >>
> >> If this makes the connection appear in pcb, let us know - and I'll
> >> see if anyone working on the gEDA side of things has any ideas for
> >> a fix, or better work around.
> >>
> >> I have an idea that I've made some boards with netlists that
> >> featured Rdummy1 Rdummy2 etc.... and I think I was working around
> >> the same issue you describe.
> >>
> >> Peter
> >> On 22 Feb 2016 21:03, "Smilie (smilie AT posteo DOT de) [via
> >> geda-help AT delorie DOT com]" <geda-help AT delorie DOT com> wrote:
> >>
> >>> Hallo Guys,
> >>>
> >>> i have a problem with my net or netname-attributes.
> >>>
> >>> I have a connector with some io-1.sym's with attributes like this:
> >>> net="abcd:1".
> >>> Than i have a PGND.sym connected to the other io-1.sym's.
> >>> They have also the attribs net="abcd:1".
> >>>
> >>> I wont tho have a connection between the connector and the pgnd
> >>> but there is no connection in pcb.
> >>>
> >>> What is wrong?
> >>>
> >>> Thanks for helping me.
> >>>
> >
> >
>
> John Doty Noqsi Aerospace, Ltd.
> http://www.noqsi.com/
> jpd AT noqsi DOT com
>
>
- Raw text -