On Feb 23, 2016, at 6:09 AM, Smilie (smilie AT posteo DOT de) [via =
geda-help AT delorie DOT com] <geda-help AT delorie DOT com> wrote:
> Ah, i see.
>=20
>=20
> i have connected a line from GND.sym direct to one of the GND-Pins and
> the other GND-Pin works also.
What are you trying to do here?
What these symbols do is to give a net a name. That=92s all. Naming the =
net connected to a pin GND connects it to all other nets named GND. If =
you have more than one such symbol, and the names don=92t match, =
gnetlist will choose the first one it sees.
Is your net connected to anything?
>=20
> It is a bug?
> I broke my head....
>=20
> Thanks for helping me.
>=20
>=20
>=20
>=20
> Am Tue, 23 Feb 2016 10:20:16 +0000
> schrieb "Peter Clifton (petercjclifton AT googlemail DOT com) [via
> geda-help AT delorie DOT com]" <geda-help AT delorie DOT com>:
>=20
>> Sorry I'm not currently able to check this out, but I recall that
>> gnetlist has (in the past, and possibly currently), not worked
>> properly in the case where only IO symbols with net=3D....:1 =
attributes
>> (but no actual components).
>>=20
>> My recollection is not that clear, but try adding a dummy component
>> (perhaps a resistor), with one pin connected on your schematic where
>> you join PGND and your IO sym. Don't need to give it a footprint
>> (but you will probably get complaints from pcb about the missing
>> component).
>>=20
>> If this makes the connection appear in pcb, let us know - and I'll
>> see if anyone working on the gEDA side of things has any ideas for a
>> fix, or better work around.
>>=20
>> I have an idea that I've made some boards with netlists that featured
>> Rdummy1 Rdummy2 etc.... and I think I was working around the same
>> issue you describe.
>>=20
>> Peter
>> On 22 Feb 2016 21:03, "Smilie (smilie AT posteo DOT de) [via
>> geda-help AT delorie DOT com]" <geda-help AT delorie DOT com> wrote:
>>=20
>>> Hallo Guys,
>>>=20
>>> i have a problem with my net or netname-attributes.
>>>=20
>>> I have a connector with some io-1.sym's with attributes like this:
>>> net=3D"abcd:1".
>>> Than i have a PGND.sym connected to the other io-1.sym's.
>>> They have also the attribs net=3D"abcd:1".
>>>=20
>>> I wont tho have a connection between the connector and the pgnd but
>>> there is no connection in pcb.
>>>=20
>>> What is wrong?
>>>=20
>>> Thanks for helping me.
>>>=20
>=20
>=20
John Doty Noqsi Aerospace, Ltd.
http://www.noqsi.com/
jpd AT noqsi DOT com
--Apple-Mail=_D1386B30-A43F-40C5-854C-16109B0E9326
Content-Transfer-Encoding: 7bit
Content-Disposition: attachment;
filename=signature.asc
Content-Type: application/pgp-signature;
name=signature.asc
Content-Description: Message signed with OpenPGP using GPGMail
-----BEGIN PGP SIGNATURE-----
Comment: GPGTools - https://gpgtools.org
iQIcBAEBCgAGBQJWzHSyAAoJEF1Aj/0UKykRcFgP/1B4Oyu7eCmHF86caSBl7xaU
W6nLNBnh9BNgDaMNFh/8/z8wcQkWrlpf84gMWZTnqLF71HKzU0lITl3rwDxzPzSc
cmn+uEB3phG+N+Ox6zVdwOuC0e45On4FibcBP4/bUkbTbXzPsABqw4LjAw5kYmT0
zadkZTOc9U85HAHv3YcXNu5xEMTa9Ts1vyoqZenSPKzDyePHhzoBWnNPs7i6y4rY
rDYEfmpLSnPF0MwyCCktUBNHnFef5z9pEIl16VmiH+SY1c3OtOQeQ3eX0UBt0IBd
io7OVJCvrhuZ9te25AeI8xOEMQ/9jJSdlfC/s/YLEjAZw5O5yNOGrHFGoSUGIaHl
YK3VSA3Y+uPDY0XwGLaDnP9RXzPooIiJEadJkHSfuqGOP/ZXYTi0TEVY9rawIzm8
xWXM5jhgQsBN7aEAXKMaQChbxqRKoqPG+riqvvE5AGwA//tJhtlXCtyrY/fhgC6E
uF1JfmpwXS1FeyrbOSQITfOefy6OpxkwiDxeH+EN20A6zdNqD6bKlhpRojqkLAWP
wigvovDP/zWK1xV+A9jZ7gC7Zx9+1cVCmX/CuUVMmLS8F0oIf8G0jP92x1EpV1d4
j+QHhOGD6M0JXUM1+hqqbbxWlDqZF13ZIUtEreiTVUMPkGW6qsYfsLdezPnGwNT5
zspY0rpam6ncBkHJN7PY
=RC8t
-----END PGP SIGNATURE-----
--Apple-Mail=_D1386B30-A43F-40C5-854C-16109B0E9326--
- Raw text -