delorie.com/archives/browse.cgi | search |
X-Authentication-Warning: | delorie.com: mail set sender to geda-help-bounces using -f |
X-Recipient: | geda-help AT delorie DOT com |
DKIM-Signature: | v=1; a=rsa-sha256; c=relaxed/relaxed; |
d=gmail.com; s=20120113; | |
h=mime-version:in-reply-to:references:from:date:message-id:subject:to | |
:content-type; | |
bh=1rG45rk3arwSm7sITbfx4Q5GCm0cZ5PWz0hanrzRCSA=; | |
b=C2qfEb+pss3EX4SL8NWpMk285EZ8v14Qq7RYCSzY+vwjM+SVRZCchnToD8SFVFRUlN | |
+QNzkcZni4s5HpApzbpkfkiNpmHgWV2gQq4pKb2t/p8ObPt0fAMgc+1jj1PFK96YeYsE | |
AZIdNGVP7XhstINaSO9nKO7tU7FCX7ZnawXmiGsKnkmMJOubTZ6zK2Y90XSeNboIteSO | |
6Ppfx96w3Y5zXEwf2IEfPkN3OOZfT53MXDZhUrCJbijDLWyHyr0+SiUbIdEqOavOjuQ3 | |
FpirjfbIaJq3lttQBkwZ30XI3y5E7Yz2XvqvnI9Q6e2SAW0l6gqovNJ45iyNTh5tFgJH | |
ePuw== | |
X-Received: | by 10.224.137.9 with SMTP id u9mr29484530qat.24.1404566899345; |
Sat, 05 Jul 2014 06:28:19 -0700 (PDT) | |
MIME-Version: | 1.0 |
In-Reply-To: | <20140705131833.GC23726@jarvis> |
References: | <20140705131833 DOT GC23726 AT jarvis> |
From: | Kadal Amutham <vkadal AT gmail DOT com> |
Date: | Sat, 5 Jul 2014 18:57:39 +0530 |
Message-ID: | <CAFaxEmVgPCnjeXqF_VJG8mtzEdNqDgrA3T=76RXpXVids=2eGA@mail.gmail.com> |
Subject: | Re: [geda-help] Gnetlist DRC Errors |
To: | "geda-help AT delorie DOT com" <geda-help AT delorie DOT com> |
Reply-To: | geda-help AT delorie DOT com |
Errors-To: | nobody AT delorie DOT com |
X-Mailing-List: | geda-help AT delorie DOT com |
X-Unsubscribes-To: | listserv AT delorie DOT com |
--001a11c2918219503604fd723792 Content-Type: text/plain; charset=UTF-8 I was using Kicad for 2-years. Now the freeroute.net is no more to do autorouting. Is geda has built in auto routing? With Warm Regards V.Kadal Amutham 919444360480 914422396480 On 5 July 2014 18:48, Abdallah Ismail <abdallah DOT ismail DOT 2 AT gmail DOT com> wrote: > Hello, > Attached is a schematic file that contains two connectors connected > together. The symbol file of the connectors is also attached. I run > > gnetlist -g drc2 -o drc > > and I get (formatted output): > > ... > Checking unconnected pins... > ERROR: Unconnected pin J2:1 > ERROR: Unconnected pin J2:2 > ERROR: Unconnected pin J2:3 > ERROR: Unconnected pin J2:4 > ERROR: Unconnected pin J2:6 > ERROR: Unconnected pin J2:8 > ERROR: Unconnected pin J1:1 > ERROR: Unconnected pin J1:2 > ERROR: Unconnected pin J1:3 > ERROR: Unconnected pin J1:4 > ERROR: Unconnected pin J1:6 > ERROR: Unconnected pin J1:8 > ... > > even though the schematic does not leave any pins unconnected. What am I > doing wrong? Below are the contents of my local gafrc, gschemrc, drcrules, > and attribs files. > > gafrc: > (component-library \"library/symbol\" \"project\") > (make-backup-files \"disabled\") > gschemrc: > (third-button \"mousepan\") > (define default-titleblock \"TITLE-B.sym\") > drcrules: > attribs: > value > comment > footprint > distributor > manufacturer > part > price > > Thank you. > --001a11c2918219503604fd723792 Content-Type: text/html; charset=UTF-8 Content-Transfer-Encoding: quoted-printable <div dir=3D"ltr">I was using Kicad for 2-years. Now the <a href=3D"http://f= reeroute.net">freeroute.net</a> is no more to do autorouting. Is geda has b= uilt in auto routing?</div><div class=3D"gmail_extra"><br clear=3D"all"><di= v><div dir=3D"ltr"> With Warm Regards<br><br>V.Kadal Amutham<div><div>919444360480<div>91442239= 6480</div></div></div></div></div> <br><br><div class=3D"gmail_quote">On 5 July 2014 18:48, Abdallah Ismail <s= pan dir=3D"ltr"><<a href=3D"mailto:abdallah DOT ismail DOT 2 AT gmail DOT com" target= =3D"_blank">abdallah DOT ismail DOT 2 AT gmail DOT com</a>></span> wrote:<br><blockquot= e class=3D"gmail_quote" style=3D"margin:0 0 0 .8ex;border-left:1px #ccc sol= id;padding-left:1ex"> Hello,<br> Attached is a schematic file that contains two connectors connected togethe= r. The symbol file of the connectors is also attached. I run<br> <br> =C2=A0gnetlist -g drc2 -o drc<br> <br> and I get (formatted output):<br> <br> ...<br> Checking unconnected pins...<br> ERROR: Unconnected pin J2:1<br> ERROR: Unconnected pin J2:2<br> ERROR: Unconnected pin J2:3<br> ERROR: Unconnected pin J2:4<br> ERROR: Unconnected pin J2:6<br> ERROR: Unconnected pin J2:8<br> ERROR: Unconnected pin J1:1<br> ERROR: Unconnected pin J1:2<br> ERROR: Unconnected pin J1:3<br> ERROR: Unconnected pin J1:4<br> ERROR: Unconnected pin J1:6<br> ERROR: Unconnected pin J1:8<br> ...<br> <br> even though the schematic does not leave any pins unconnected. What am I do= ing wrong? Below are the contents of my local gafrc, gschemrc, drcrules, an= d attribs files.<br> <br> gafrc:<br> =C2=A0 =C2=A0 (component-library \"library/symbol\" \"projec= t\")<br> =C2=A0 =C2=A0 (make-backup-files \"disabled\")<br> gschemrc:<br> =C2=A0 =C2=A0 (third-button \"mousepan\")<br> =C2=A0 =C2=A0 (define default-titleblock \"TITLE-B.sym\")<br> drcrules:<br> attribs:<br> =C2=A0 =C2=A0 value<br> =C2=A0 =C2=A0 comment<br> =C2=A0 =C2=A0 footprint<br> =C2=A0 =C2=A0 distributor<br> =C2=A0 =C2=A0 manufacturer<br> =C2=A0 =C2=A0 part<br> =C2=A0 =C2=A0 price<br> <br> Thank you.<br> </blockquote></div><br></div> --001a11c2918219503604fd723792--
webmaster | delorie software privacy |
Copyright © 2019 by DJ Delorie | Updated Jul 2019 |