delorie.com/archives/browse.cgi | search |
X-Authentication-Warning: | delorie.com: mail set sender to geda-help-bounces using -f |
Date: | Thu, 19 Dec 2013 01:08:32 -0500 |
Message-Id: | <201312190608.rBJ68W4d021122@envy.delorie.com> |
From: | DJ Delorie <dj AT delorie DOT com> |
To: | geda-help AT delorie DOT com |
In-reply-to: | |
<CALT8Ef5XtuaPY4QjAw=658ZaL_sV38CbX0aqgosRvOVdG5BmKA AT mail DOT gmail DOT com> | |
(message from Shashank Chintalagiri on Thu, 19 Dec 2013 11:11:09 | |
+0530) | |
Subject: | Re: [geda-help] PCB segfault on opening specific PCBs |
References: | <CALT8Ef5XtuaPY4QjAw=658ZaL_sV38CbX0aqgosRvOVdG5BmKA AT mail DOT gmail DOT com> |
Reply-To: | geda-help AT delorie DOT com |
Looks like CreateNewNet() has a hardcoded limit of 63 characters for net names, but doesn't check the length coming from the schematic. Did you add or rename a net using a long name? Or are you using heirarchy? (and yes, please add a bug report to launchpad if there isn't one already)