delorie.com/archives/browse.cgi | search |
Message-ID: | <03a701c2ccf6$5ccd6160$0600000a@broadpark.no> |
From: | "Gisle Vanem" <giva AT bgnett DOT no> |
To: | <djgpp AT delorie DOT com> |
References: | <b1qcar$16070j$1 AT ID-83062 DOT news DOT dfncis DOT de> |
Subject: | Re: Determining interrupt vector for serial port |
Date: | Wed, 5 Feb 2003 10:10:00 +0100 |
MIME-Version: | 1.0 |
X-Priority: | 3 |
X-MSMail-Priority: | Normal |
X-Mailer: | Microsoft Outlook Express 6.00.2800.1123 |
X-MIMEOLE: | Produced By Microsoft MimeOLE V6.00.2800.1123 |
Reply-To: | djgpp AT delorie DOT com |
"John Henderson" <jhenRemoveThis AT bigpond DOT com> said: > But I've been unable to discover how to "read" the associated IRQ > value for each port. So far I've found them hardcoded as 4, 3, > 4, 3 respectively in all examples. But I've got to look no > further than my own PC to find COM3 using IRQ5 (on an ISA card). > How does a program discover this? Only way I know is to 1. mask off all interrupts in the PIC (to prevent false positives) 2. clear the in-service bits 3. issue an UART command that raises it's IRQ line (e.g. an internal loopback test) 4. poll all in-service bits in the PIC 5. and finally restore the PIC mask. A lot of work to automate. A IMHO nicer approach would be to use an environment variable so the user can override default assumptions. E.g. COM1_SETTINGS=irq 5, base 0x3f8 Gisle V.