delorie.com/archives/browse.cgi   search  
Mail Archives: cygwin/1998/10/17/20:25:52

From: bob AT xware DOT it (Roberto Biancardi)
Subject: snapshot 981012 serial port problems
17 Oct 1998 20:25:52 -0700 :
Message-ID: <3628C36B.30334963.cygnus.gnu-win32@xware.it>
Mime-Version: 1.0
To: gnu-win32 AT cygnus DOT com

i'am using b19+binutils 2.9.1+winsup981012+newlib980824.  No egcs.
I'am in trouble with serial ports.
'comx' device names don't works anymore because of missing strcmp(,"com1") in
hinfo.cc;
may be this is right i don't know. But,
'/dev/comx' devices don't work because get_native of class fhandler_serial is
never called so
the win32_path_name_ remains /dev/com%d.

I did this simple fix just to go on, but after that it seems data from serial
ports is not
coming in at all. Anybody involved in similar troubles ?

 --- /tmp/fhandler_serial.cc     Sat Oct 17 18:11:01 1998
+++ fhandler_serial.cc  Sat Oct 17 02:12:03 1998
@@ -24,6 +24,10 @@
   vmin_ = 0;
   vtime_ = 0;
   pgrp_ = myself->pgid;
+#ifndef        turn_off_my_changes
+       if ( name != NULL )
+               set_name(name, get_native()+5);
+#endif
 }

 const char *


--
Roberto Biancardi - +39 2 22475231 - bob AT xware DOT it



-
For help on using this list (especially unsubscribing), send a message to
"gnu-win32-request AT cygnus DOT com" with one line of text: "help".