Category: DESQview/TopView and Quarterdeck programs

INT 15 - TopView - SEND MESSAGE - "READN" - GET NEXT N OBJECT BYTES

	AH = 12h
	BH = 12h
	BL = window to read from
	    00h handle is DWORD on top of stack
	    01h read next N chars or attributes on task's default window
	    0Ch (DV 2.26+) read window of task owning handle on top of stack
	    0Dh (DV 2.26+) read default window of parent of current task
	STACK: DWORD count
Return: STACK: DWORD number of bytes actually read
	       DWORD address of buffer containing data
Notes:	reading starts at the current logical cursor position; the cursor is
	  updated to point at the character following the last one read
	any translucent blanks (FFh) which are visible on screen are changed
	  to the character which is seen through them
	the string produced by the read is placed in an input buffer which may
	  be reused by the next READ or READN of a window
	window stream opcodes D8h and D9h determine whether the read returns
	  characters or attributes
SeeAlso: AH=12h/BH=04h"WINDOW",AH=12h/BH=05h"WINDOW"