X-Authentication-Warning: delorie.com: mail set sender to geda-user-bounces using -f X-Recipient: geda-user AT delorie DOT com X-Original-DKIM-Signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=gmail.com; s=20161025; h=mime-version:from:date:message-id:subject:to; bh=gEL32nqWTc23L3gKKkIHfQ47ATOu7NwybV9FmfPZrjc=; b=YiLS6rh6M6Xr7lKLI7p45yV7U18s3voG/os7WO6kX4Hfdge3yw3c3Sx7qIaGBR2faj j1x2v5L4feRqTJO6AAmKnVyu2TkLkcK+6nfox3qhCnDYd94QgAos92Ra2Go8NYsGpCdL cTxqlZzDa3CGUQUeXnmElhpQsPXpenbkQUotlOzgK99RNwi5UGVMV5uPoiOBZJy+pYQZ mcG2CpGtFJne+7RtZ5lnUk6tHF6dU/refRhWNDzjPJcyh/X8SY8JcN8k+vVC2sZHvrQN En0xNCvr10XEldl1K0X9HvUWvAX9AhT3oCEdztwP5e/sKdiBb9SzJ9C7+uRvcryyN+Qo 0CxQ== X-Google-DKIM-Signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=1e100.net; s=20161025; h=x-gm-message-state:mime-version:from:date:message-id:subject:to; bh=gEL32nqWTc23L3gKKkIHfQ47ATOu7NwybV9FmfPZrjc=; b=ZLfXaCVot1LbjBCvgx9+eln+iaRsa1CzEvZSQRIb85Sx4QI72xXgwTZ0UHFkmCGvAN GkUYweUsi18jjuWzBZEXDT54MKb0OjVZ2R/YMEFwBKwxkC4Wp34PXY7wJmUziPaNv6Fg Osv8MjN5YaBl87gHYHcjHjP/j3psF/oy6xwNsvWzd9A78FbzGHU76IEi7SihDqC8+ECe oWrIAp8h2+01MnzgvUPVGjK9zqhKQBjAIwzsjzsxaWkPYgyTqShi4kuI/AwPjtYWX0X2 5bRqnzTKf9waaDQDTogj6RKSCrywsEkmkpW+Wj+g77HIT06I7OIEF3/Xn6gAv1gwpeCe 1dww== X-Gm-Message-State: AOAM530fiXTtOF5XXsLzaQMSFHyxI+MwLykfKwmVeDc3wSe4b7TDz0Sh 3x0ZuQsQHW473xl0EF0RaXBqdupVBDkk4p6h6Dn76A== X-Google-Smtp-Source: ABdhPJxXwC71HINowPtuqmHDxjI6jtmGK+fxYwG8UGSInOOnVxCkzWPJO4MkekvtZ2jgPupl8CfTluvhZi2wrxo/SqU= X-Received: by 2002:a25:1045:: with SMTP id 66mr49359502ybq.314.1591149189162; Tue, 02 Jun 2020 18:53:09 -0700 (PDT) MIME-Version: 1.0 From: "Britton Kerin (britton DOT kerin AT gmail DOT com) [via geda-user AT delorie DOT com]" Date: Tue, 2 Jun 2020 17:52:58 -0800 Message-ID: Subject: [geda-user] getting pcb to figure out that the netname for a wire has changed in gschem To: geda-user AT delorie DOT com Content-Type: text/plain; charset="UTF-8" Reply-To: geda-user AT delorie DOT com I just recently started using named nets in gschem rather than just drawing wires everywhere. Now I have an issue where I remove a netname=foo attribute from one net and put it on another. pcb still seems to think the old connection (to the wire with the removed netname=foo attribute) should exist. How do I tell it it shouldn't? I tried opening up the netlist window but no net with name foo show up there at all. I vaguely remember that before "Import schematics" gsh2pcb would tell you to run some netlist-related command from inside pcb afterwords. Maybe I still need to do that? If so could someone remind me what it might be? Thanks, Britton