> _/p12/unnamed_net42     _p12C2-1 _p12Dsw-1 _p12Dsw-2 _p12Dsw-5 _p12Dsw-6 _p12L1-2 _p12U1-6

Try taking the "sw" off, or replacing it with "SW".  For antique
reasons, pcb treats lower case suffixes as gate references, separate
from the refdes.